Development and external validation of temporal fusion transformer models for continuous intraoperative blood
Lorenz Kapral1,2,3, Christoph Dibiasi1,2, Natasa Jeremic4
1Medical University of Vienna, Department of Anaesthesia, Intensive Care Medicine and Pain Medicine, Währinger Gürtel 18-20, Vienna 1090, Austria.
Background:
During surgery, intraoperative hypotension is associated with postoperative morbidity and should therefore be avoided. Predicting the occurrence of hypotension in advance may allow timely interventions to prevent hypotension. Previous prediction models mostly use high-resolution waveform data, which is often not available.
Methods:
We utilised a novel temporal fusion transformer (TFT) algorithm to predict intraoperative blood pressure trajectories 7 min in advance. We trained the model with low-resolution data (sampled every 15 s) from 73,009 patients who were undergoing general anaesthesia for non-cardiothoracic surgery between January 1, 2017, and December 30, 2020, at the General Hospital of Vienna, Austria. The data set contained information on patient demographics, vital signs, medication, and ventilation. The model was evaluated using an internal (n = 8113) and external test set (n = 5065) obtained from the openly accessible Vital Signs Database.
Findings:
In the internal test set, the mean absolute error for predicting mean arterial blood pressure was 0.376 standard deviations-or 4 mmHg-and 0.622 standard deviations-or 7 mmHg-in the external test set. We also adapted the TFT model to binarily predict the occurrence of hypotension as defined by mean arterial blood pressure < 65 mmHg in the next one, three, five, and 7 min. Here, model discrimination was excellent, with a mean area under the receiver operating characteristic curve (AUROC) of 0.933 in the internal test set and 0.919 in the external test set.
Interpretation:
Our TFT model is capable of accurately forecasting intraoperative arterial blood pressure using only low-resolution data showing a low prediction error. When used for binary prediction of hypotension, we obtained excellent performance.
Funding:
No external funding.
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Errors occurring during blood pressure monitoring
Several factors...
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.