Pulse signal may be a key bridge connecting cardiology and pulse diagnosis of TCM
Qingfeng Tang1,2, Yan-Kun Chen3, Shiping Liu1
1Digital and Intelligent Health Research Center, Anqing Normal University, Anqing 246133, China.
Objective:
This study extracts atherosclerosis indices from six channels of and discusses the data distribution, aims to explore the connection between cardiology of modern medicine (MM) and traditional Chinese medicine (TCM) pulse diagnosis.
Methods:
We use a device capable of simultaneously collecting the pulse signals of the Cun, and Chi to test the population participating in routine physical examinations. Firstly, we collected pressure pulse waves from six channels of of 1045 healthy subjects (578 men and 467 women, average age=37.99±16.02 years). Secondly, we extracted the two most common arteriosclerosis indices pulse transit time (PTT) and Augmentation index (AIx) from six-channel pulse waves. Lastly, T-test and correlation test were taken to analyze the differences and relevance of the atherosclerosis indices extracted from six channels of .
Results:
When analyzing AIx and PTT at different wrist, it was found that AIx of left wrist is significantly higher than that of right wrist (P<0.001), while the PTT of left wrist is significantly lower than that of right wrist (P<0.001), a phenomenon that is common in both men and women. Furthermore, regardless of whether it is left or right wrist, the AIx at Chi channel is higher than that at Cun (P<0.05) and (P<0.05). At the same time, the PTT at is bigger than that at Cun in two wrists (P<0.05). However, when the specific channel is not considered, there is no significant difference in AIx and PTT between each channel and the corresponding wrist (P>0.05). In addition, regardless of gender, when the specific channel is not considered, AIx and PTT of each wrist are significantly correlated with age (P<0.001).
Conclusions:
The differences of the atherosclerosis indices AIx and PTT in six channels support that the method of six-channel pulse diagnosis is indispensable in TCM. Additionally, the pulse waves obtained from each channel can be utilized as a dependable foundation for diagnosing atherosclerotic conditions. This study is beneficial for promoting the integration of TCM and MM in diagnosing disease.
More Related Videos
07:53Standardized Rat Coronary Ring Preparation and Real-Time Recording of Dynamic Tension Changes Along Vessel Diameter
Published on: June 16, 2022
06:16Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
Published on: August 9, 2024
Related Concept Videos
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Special considerations while measuring pulse
Pulse
The pulse serves as a clinical...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Pulse Assessment Sites
Regulation of Pulse