Operation map of a traveling-wave thermoacoustic electric generator with variable resistive-capacitive electric loads

Abdelmaged H Ibrahim1,2, Khaled Elbeltagy1, Islam Ramadan3

  • 1School of Science and Engineering, American University in Cairo, New Cairo 11835, Egypt.

Related Concept Videos

Electric Generator: Alternator01:25

Electric Generator: Alternator

Electric generators induce an emf by rotating a coil in a magnetic field. A simple alternator is an AC generator that creates electrical energy that varies sinusoidally with time. A simple alternator consists of a conducting loop that is placed inside a uniform magnetic field. The loop is connected to split rings connected to the external circuit with the help of brushes.
The magnetic flux passing through the coil varies sinusoidally as the loop rotates inside the magnetic field. This...
2.5K
DC Generator01:19

DC Generator

An alternator converts mechanical energy into electrical energy that varies sinusoidally, resulting in AC current. Meanwhile, a DC generator converts mechanical energy into electrical energy, which are DC pulses with the same polarity. The construction of a DC generator is similar to that of an alternator, except that the pair of slip rings is replaced by a single split ring, also called a commutator. The commutator functions like a periodic rotary switch; it changes the contacts with the...
691
Control of Power Flow01:30

Control of Power Flow

There are several methods to control power flow in power systems:
255
Generator Voltage Control01:21

Generator Voltage Control

Generator voltage control is crucial for maintaining the stable operation of synchronous generators and wind turbines. In older models, a DC generator driven by the rotor delivers DC power to the rotor's field winding, and the power is transferred through slip rings and brushes. In the latest models, static or brushless exciters are used. Static exciters rectify AC power from the generator terminals and then transfer the DC power directly to the rotor. Brushless exciters, on the other hand,...
137
Equivalent Circuits for Practical Transformers01:28

Equivalent Circuits for Practical Transformers

The practical equivalent circuits of single-phase two-winding transformers exhibit significant deviations from their idealized versions due to the inherent properties of winding resistance and finite core permeability. These properties result in real and reactive power losses, affecting the transformer's performance. Understanding these deviations is crucial for designing more efficient transformers.
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
401
Generation of Three-Phase Voltage01:21

Generation of Three-Phase Voltage

A three-phase AC generator has a rotor with a rotating magnet placed within the stator mounted with the stationary three-phase winding to generate three-phase voltages via mutual induction. These windings are evenly distributed around the inner circumference of the stator and are arranged 120 electrical degrees apart. Three-phase stator windings consist of three separate coils or groups of coils, known as phases, each connected in Y (star) configuration or Delta configuration.
As the rotor...
365