Related Experiment Video
Updated: Jun 13, 2025

Author Spotlight: Computing the Effects of a Local Radiofrequency Hyperthermia Intervention on Tumor Biomechanics
Published on: December 1, 2023
Computer simulation of low-power and long-duration bipolar radiofrequency ablation under various baseline impedances
Yao Sun1, Xin Zhu1, Wenxi Chen1
1Graduate Department of Computer Science and Engineering, The University of Aizu, Aizuwakamatsu, Fukushima 965-8580, Japan.
Abstract:
Compared to traditional unipolar radiofrequency ablation (RFA), bipolar RFA offers advantages such as more precise heat transfer and higher ablation efficiency. Clinically, myocardial baseline impedance (BI) is one of the important factors affecting the effectiveness of ablation. We aim at finding suitable ablation protocols and coping strategies by analyzing the ablation effects and myocardial impedance changes of bipolar RFA under different BIs. In this research, a three-dimensional local myocardial computer model was constructed for bipolar RFA simulation, and in vitro experimental data were used to validate accuracy. Four fixed low-power levels (20 W, 25 W, 30 W, and 35 W) and six myocardial BIs (91.02 Ω, 99.83 Ω, 111.03 Ω, 119.77 Ω, 130.03 Ω, and 135.45 Ω) were set as initial conditions, with an ablation duration of 120-s. In the context of low-power and long-duration (LPLD) ablation, the maximum TID (TIDM) decreased by 21-32 Ω, depending on the BI. In cases where steam pop did not occur, TIDM increased with the increase in power. For the same power, there was no significant difference in TIDM for the range of BIs. In cases where steam pop occurred, for every 1 Ω increase in BI, TIDM increased by 0.34-0.41 Ω. The simulation results also showed that using a higher power resulted in a smaller decrease in TIDM. This study provided appropriate ablation times and impedance decrease ranges for bipolar LPLD RFA. The combination of 25 W for 120-s offered optimal performance when considering effectiveness and safety simultaneously.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
05:43Author Spotlight: Improving Lesion Contiguity in Pulmonary Vein Isolation via Proactive Esophageal Cooling
Published on: April 19, 2024
Related Concept Videos
Mesh Analysis for AC Circuits
The process of harmonizing these impedances begins with a clear understanding of the input and output signals. Once these signals are known, the...
Frequency Response of BJT
Low-Frequency Response: At low frequencies, the behavior of the BJT is determined by its DC bias point, which is set by the...