Related Experiment Video
Updated: Apr 7, 2026

Guidelines and Experience Using Imaging Biomarker Explorer IBEX for Radiomics
Published on: January 8, 2018
Investigation of ComBat Harmonization on Radiomic and Deep Features from Multi-Center Abdominal MRI Data
Wei Jia1,2, Hailong Li1,3, Redha Ali1
1Imaging Research Center, Department of Radiology, Cincinnati Children's Hospital Medical Center, 3333 Burnet Avenue, MLC 7009, Cincinnati, OH, 45229, USA.
Abstract:
ComBat harmonization has been developed to remove non-biological variations for data in multi-center research applying artificial intelligence (AI). We investigated the effectiveness of ComBat harmonization on radiomic and deep features extracted from large, multi-center abdominal MRI data. A retrospective study was conducted on T2-weighted (T2W) abdominal MRI data retrieved from individual patients with suspected or known chronic liver disease at three study sites. MRI data were acquired using systems from three manufacturers and two field strengths. Radiomic features and deep features were extracted using the PyRadiomics pipeline and a Swin Transformer. ComBat was used to harmonize radiomic and deep features across different manufacturers and field strengths. Student's t-test, ANOVA test, and Cohen's F score were applied to assess the difference in individual features before and after ComBat harmonization. Between two field strengths, 76.7%, 52.9%, and 26.7% of radiomic features, and 89.0%, 56.5%, and 0.1% of deep features from three manufacturers were significantly different. Among the three manufacturers, 90.1% and 75.0% of radiomic features and 89.3% and 84.1% of deep features from two field strengths were significantly different. After ComBat harmonization, there were no significant differences in radiomic and deep features among manufacturers or field strengths based on t-tests or ANOVA tests. Reduced Cohen's F scores were consistently observed after ComBat harmonization. ComBat harmonization effectively harmonizes radiomic and deep features by removing the non-biological variations due to system manufacturers and/or field strengths in large multi-center clinical abdominal MRI datasets.
More Related Videos
02:09Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
Published on: April 12, 2024
09:43Multimodal Study of Murine Cardiovascular Remodeling: Four-Dimensional Ultrasound and Mass Spectrometry Imaging
Published on: January 10, 2025