Related Experiment Video
Updated: May 13, 2026

12:54
Detection of Foodborne Bacterial Pathogens from Individual Filth Flies
Published on: February 13, 2015
18.3K
Comparison of Roka Atlas® System Performance and Health Canada Reference Method for Listeria Detection From Plastic,
Fereidoun Forghani1, Eni Themeli1, Tam Mai1
1Molecular Epidemiology, Inc, 15300 Bothell Way NE, Lake Forest Park, WA 98155, USA.
Journal of AOAC International
|September 17, 2024
Summary
The Roka Atlas System offers rapid, accurate detection of Listeria species on various surfaces, comparable to reference methods. This automated system provides high sensitivity and specificity, even after short enrichment periods.
Area of Science:
- Food safety and public health microbiology
- Rapid diagnostic methods for microbial detection
Background:
- High demand for automated, high-volume sample processing methods in the food industry and public health.
- Need for rapid and reliable pathogen detection to ensure food safety and public health.
Purpose of the Study:
- To evaluate the performance of the Roka Atlas® System for detecting Listeria spp. and Listeria monocytogenes.
- To compare the Roka Atlas System with a Health Canada reference method on plastic, sealed concrete, and stainless-steel surfaces.
Main Methods:
- An unpaired study design was used to compare the Roka Atlas System with the Health Canada reference method (MFHPB-30).
- The Roka Atlas assay was tested with R2 medium pre-enrichment for 14, 16, and 24 hours at 35°C.
- Inoculation of surfaces (plastic, sealed concrete, stainless-steel) with Listeria species, including competing microorganisms.
Main Results:
- The Roka Atlas System demonstrated 100% sensitivity and 100% specificity across all tested surfaces and enrichment times.
- No false negatives or false positives were observed for the Roka Atlas System.
- Detection of true positives was comparable to the reference method across different surface types and inoculation levels.
Conclusions:
- The Roka Atlas System provides a reliable and accurate method for Listeria detection on various surfaces.
- The system achieved comparable detection probabilities to the reference method, even with a reduced enrichment time of 14 hours.
- Surface type did not impact the assay's sensitivity or specificity, highlighting its versatility.