Evaluation of a Point-of-Care Testing Analyzer for Measuring Peripheral Blood Leukocytes
Published on: March 22, 2022
Clinical Decision-Making Suffers from Inequivalent Measurement Results and Inadequate Reference Intervals
Marith van Schrojenstein Lantman1,2, Miranda van Berkel2, Philip Kuijper3
1Stichting Kwaliteitsbewaking Medische Laboratoria (SKML), Nijmegen, the Netherlands.
Background:
Appropriate clinical decision-making relies on the interpretation of equivalent measurement results in the context of valid clinical decision limits. Besides guideline-based decision limits, reference intervals (RIs) are commonly used to discriminate between abnormal results and results from "healthy" individuals. This study evaluated the suitability of RIs in light of the analytical bias for laboratories in the Netherlands using one standardized, one harmonized, and one unharmonized measurand (creatinine, hemoglobin, and ferritin, respectively).
Methods:
Three types of data were collected: (a) external quality assessment (EQA) performance data from the Dutch Foundation for Quality Assurance in Laboratory Medicine (SKML); (b) the RIs reported by laboratories for a 55-year-old female; and (c) harmonized RIs established by using unique routine patient results using RefineR. Routinely used RIs (b) were compared to the harmonized RIs (c) and evaluated in combination with the analytical bias at the lower and upper reference limits.
Results:
Laboratories reported a variety of routinely used RIs that were inconsistent with the analytical bias, with differences between measurement procedures. The use of assays that perform within allowable bias limits does not automatically guarantee that the appropriate RI is used, allowing potential for structural misinterpretation of important diagnoses in patients.
Conclusions:
The use of RIs that are inconsistent with the analytical bias causes unnecessary between-laboratory differences in clinical decision-making. Adopting harmonized RIs facilitates similar interpretation of results across facilities. Harmonized RIs can be adopted immediately if the observed bias is acceptable or eliminated, or after standardization/harmonization of measurands without complete metrological traceability.
More Related Videos
Related Concept Videos
Interval Level of Measurement
Data measured using the interval scale are similar to ordinal level data because they have a definite arrangement. However, in the interval level of measurement, the differences between data values are meaningful even though the data does not have a starting point.
Temperature is measured using the interval scale. It is measurable data, and the difference between...
Errors occurring during blood pressure monitoring
Several factors...
Uncertainty in Measurement: Reading Instruments
Uncertainty in Measurement: Accuracy and Precision
Statistical Analysis: Overview
One of the most commonly used statistical quantifiers is the mean, which is the ratio between the sum of the numerical values of all results and the...
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...