Interpenetrating Composite Hydrogel Electrolyte with Organic/Inorganic Polar Groups for Stable Zinc Metal Anode

Yaping Wang1, Jiashuo Guo1, Chao Liang2

  • 1School of Materials Science and Engineering, Hebei University of Technology, Tianjin 300130, China.

Related Concept Videos

Extraction: Advanced Methods00:56

Extraction: Advanced Methods

Metal ions can be separated from one another by complexation with organic ligands–the chelating agent– to form uncharged chelates. Here, the chelating agent must contain hydrophobic groups and behave as a weak acid, losing a proton to bind with the metal. Since most organic ligands used in this process are insoluble or undergo oxidation in the aqueous phase, the chelating agent is initially added to the organic phase and extracted into the aqueous phase. The metal-ligand complex is...
432
Ion Exchange01:17

Ion Exchange

Ion exchange chromatography separates charged molecules from a solution by reversibly exchanging them with mobile, or 'active', ions associated with the oppositely charged stationary phase. This method can be used to separate ions, soften and deionize water, and purify solutions. The polymers comprising the ion-exchange column are high-molecular-weight and chemically stable polymers, crosslinked to be porous and essentially insoluble. They are also functionalized with either acidic or...
564
Standard Electrode Potentials03:02

Standard Electrode Potentials

On comparing the reactivity of silver and lead, it is observed that the two ionic species, Ag+ (aq) and Pb2+ (aq), show a difference in their redox reactivity towards copper: the silver ion undergoes spontaneous reduction, while the lead ion does not. This relative redox activity can be easily quantified in electrochemical cells by a property called cell potential. This property is commonly known as cell voltage in electrochemistry, and it is a measure of the energy which accompanies the charge...
43.5K
Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at...
488