AAPM Task Group 21 protocol: dosimetric evaluation.

J M Paul, R F Koch, P C Philip

    Medical Physics
    |July 1, 1985
    PubMed
    Summary
    This summary is machine-generated.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    Peer review in MRI: A quality improvement programme and pilot study.

    Radiography (London, England : 1995)·2020
    Same author

    Mutations at F637 in the NMDA receptor NR2A subunit M3 domain influence agonist potency, ion channel gating and alcohol action.

    British journal of pharmacology·2007
    Same author

    Glucocorticoids upregulate taurocholate transport by ileal brush-border membrane.

    The American journal of physiology·1997
    Same author

    Downregulation of taurocholate transport by ileal BBM and liver BLM in biliary-diverted rats.

    The American journal of physiology·1994
    Same author

    Comparison between continuous and discrete sources in the Paris system of implants.

    Medical physics·1989
    Same author

    Characteristics of clometacin-induced hepatitis with special reference to the presence of anti-actin cable antibodies.

    Autoimmunity·1989
    Same journal

    Correction to "On the shape of the radiation survival curve in tumor spheroids: The role of oxygen heterogeneity".

    Medical physics·2026
    Same journal

    Multi-view constrained semi-supervised vertebra detection for 3D ultrasound spine volume.

    Medical physics·2026
    Same journal

    Accuracy of quantitative <sup>177</sup>Lu SPECT/CT imaging: A systematic review.

    Medical physics·2026
    Same journal

    Physics-constrained dual-domain network for CBCT reconstruction from orthogonal X-rays in gynecologic radiotherapy.

    Medical physics·2026
    Same journal

    Decomposition-based harmonization for quantitative PET imaging across scanners and radiotracers.

    Medical physics·2026
    Same journal

    Development and evaluation of an in vivo dose-based monitoring system for electron FLASH radiation therapy.

    Medical physics·2026
    See all related articles

    The AAPM Task Group 21 protocol requires dosimetry adjustments for 15-MV x-rays and 7-18 MeV electrons. These findings aid accurate radiotherapy dose calculations for high-energy beams.

    Area of Science:

    • Medical Physics
    • Radiotherapy Dosimetry

    Background:

    • The AAPM Task Group 21 protocol is a recent standard for high-energy x-ray and electron beam dosimetry in radiotherapy.
    • Accurate dosimetry is critical for effective and safe radiation treatment planning.

    Purpose of the Study:

    • To evaluate and adjust dosimetric parameters (C lambda and CE values) based on the AAPM Task Group 21 protocol.
    • To compare derived values with previous findings and other established protocols.

    Main Methods:

    • Calculated dose to medium for various modalities using the AAPM TG-21 protocol.
    • Verified calculations using thermoluminescent dosimetry.
    • Compared C lambda and CE values with those from the Nordic Association of Clinical Physics protocols.

    Main Results:

    Related Experiment Videos

    • A 1.6% upward adjustment is needed for the C lambda value for 15-MV x-rays.
    • A 1%-3% downward adjustment is required for CE values for electrons (7-18 MeV).
    • Thermoluminescent dosimetry confirmed the calculated dose to medium values.

    Conclusions:

    • The study provides specific adjustments to C lambda and CE values for 15-MV x-rays and 7-18 MeV electrons under the AAPM TG-21 protocol.
    • These adjustments are system-specific and require careful consideration for broader application.
    • Discrepancies with other protocols highlight the need for ongoing refinement in radiotherapy dosimetry standards.