A sensitive and robust analytical method for the determination of enramycin residues in swine tissues using

Feifei Sun1, Jicheng Qiu2,3, Jingyuan Kong2,3

  • 1Animal-Derived Food Safety Innovation Team, College of Animal Science and Technology, Anhui Agricultural University, Hefei, China.

PubMed

Insights

A new ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method accurately detects enramycin residues in swine tissues. This sensitive approach meets safety evaluation requirements for enramycin, a common animal growth promoter.

Area of Science:

  • Analytical Chemistry
  • Food Safety
  • Veterinary Pharmacology

Background:

  • Enramycin is a widely used growth promoter in poultry and swine, effective against Gram-positive bacteria.
  • Existing methods for enramycin residue detection lack the required accuracy, with limits of quantification exceeding the maximum residue limit (MRL) of 30 μg/kg.
  • Accurate quantification of enramycin is crucial for ensuring food safety and compliance with regulatory standards.

Purpose of the Study:

  • To develop and validate a highly sensitive and robust analytical method for determining enramycin residues in various swine tissues.
  • To establish a method capable of quantifying enramycin at levels below the established MRL, facilitating safety evaluations.

Main Methods:

  • Development of an ultrahigh-performance liquid chromatography coupled with tandem mass spectrometry (UHPLC-MS/MS) method.
  • Extraction of enramycin from swine tissues (liver, kidney, pork, fat) using a methanol-hydrochloric acid mixture.
  • Cleanup and enrichment of analytes using an ENV cartridge.

Main Results:

  • The UHPLC-MS/MS method demonstrated excellent linearity (coefficient of variation > 0.99) across all tested swine tissues.
  • Satisfactory recoveries (70.99-101.40%) and low relative standard deviations (< 9%) were achieved at various spiking levels.
  • The method's limit of quantification was determined to be 5 μg/kg in fat and 10 μg/kg in other tissues, meeting safety evaluation requirements.

Conclusions:

  • The developed UHPLC-MS/MS method is highly sensitive, specific, stable, and robust for enramycin residue analysis in swine tissues.
  • This novel analytical approach is suitable for the safety evaluation of enramycin in food products, ensuring compliance with regulatory limits.

Related Concept Videos