Evaluation of Changes in Cardiac Troponin I Levels After Direct Current Cardioversion in Patients With Atrial
Marina Katerini1, Christine Politi1, Olympia Konstantakopoulou2
1Cardiology Clinic, General Hospital of Pella (Hospital Unit of Edessa), Thessaloniki, GRC.
Introduction:
Direct current cardioversion (DCCV) of atrial fibrillation (AF) is a procedure used to restore normal heart rhythm. Cardiac biomarkers, such as cardiac troponin I (cTnI), are elevated in situations where injury-myocardial cell necrosis is induced.
Aim:
The aim of the present study was to investigate the change in cTnI levels, i.e., whether a myocardial injury is present, in patients with AF whose elective treatment was synchronized DCCV via a biphasic defibrillator.
Methods:
The study sample included 59 patients who underwent synchronized DCCV for AF reversion. Measurement of cTnI before and after DCCV (one, three, and six hours) was performed by blood sampling and subsequent assay.
Results:
It was observed that the value of cTnI did not change (<0.1 ng/mL) after DCCV at the measurement time points (one, three, and six hours). In addition, the value of cTnI remained constant (<0.1 ng/mL) in relation to the energy delivered, before DCCV and after DCCV (one, three, and six hours). However, it was found that there was a correlation between the outcome (AF reversion or not) and the energy used (joules).
Conclusions:
Synchronized DCCV with a biphasic defibrillator did not cause myocardial injury in any of the patients, as there was no change in cTnI values before and after DCCV.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
07:40Impact of High-intensity Interval Exercise and Moderate-Intensity Continuous Exercise on the Cardiac Troponin T Level at an Early Stage of Training
Published on: October 10, 2019
Related Concept Videos
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Heart Failure Drugs: Inotropic Agents
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...