Related Experiment Video
Updated: Jun 12, 2025

Author Spotlight: Unveiling Transmembrane Protein Family-Related Markers in Gastric Cancer and Implications for Targeted Therapies
Published on: September 15, 2023
External quality assessment-based tumor marker harmonization simulation; insights in achievable harmonization for CA
Huub H Van Rossum1, Stefan Holdenrieder2, Yeo-Min Yun3
1Department of Laboratory Medicine, Netherlands Cancer Institute, Amsterdam, The Netherlands.
Harmonizing measurement procedures for CA 15-3 and CEA tumor markers significantly improves accuracy. Recalibrating a limited number of methods greatly reduces bias, enhancing clinical care for breast and colorectal cancer patients.
Area of Science:
- Clinical Chemistry
- Laboratory Medicine
- Biomarker Analysis
Background:
- CA 15-3 and CEA are crucial tumor markers for breast and colorectal cancers.
- Current measurement procedures (MP) for these markers lack sufficient harmonization.
- Inconsistent results hinder reliable clinical interpretation and patient management.
Purpose of the Study:
- To investigate achievable harmonization for CA 15-3 and CEA tumor markers.
- To simulate external quality assessment (EQA) data using patient-pool based samples.
- To evaluate the impact of a defined harmonization protocol on measurement procedure bias.
Main Methods:
- Utilized CA 15-3 and CEA data from SKML, UK NEQAS, and KEQAS EQA programs.
- Defined a harmonization protocol involving MP equivalence and bias assessment (>5%).
- Assessed harmonization status via mean agreement and residual variation (CV %).
Main Results:
- Limited MPs (Abbott, Beckman, Roche, Siemens) were common across EQA programs.
- Recalibration was proposed for Beckman (CA 15-3) and Siemens (CEA) MPs.
- Harmonization reduced CA 15-3 mean bias range from -29.28% to 9.86% to -0.09% to 0.12%.
- Harmonization reduced CEA mean bias range from -23.78% to 2.00% to -3.13% to 1.42%.
Conclusions:
- Significant improvement in CA 15-3 and CEA harmonization is achievable.
- Recalibration of a limited number of measurement procedures is effective.
- Enhanced harmonization supports more reliable tumor marker testing in clinical practice.