Calibration-free whole-brain CEST imaging at 7T with parallel transmit pulse design for saturation homogeneity
Yannik Völzke1, Suzan Akbey1, Daniel Löwen1
1German Center for Neurodegenerative Diseases (DZNE), Bonn, Germany.
Purpose:
Chemical exchange saturation transfer (CEST) measurements at ultra-high field (UHF) suffer from strong saturation inhomogeneity. Retrospective correction of this inhomogeneity is possible to some extent, but requires a time-consuming repetition of the measurement. Here, we propose a calibration-free parallel transmit (pTx)-based saturation scheme that homogenizes the saturation over the imaging volume, which we call PUlse design for Saturation Homogeneity utilizing Universal Pulses (PUSHUP).
Theory:
Magnetization transfer effects depend on the saturation . PUSHUP homogenizes the saturation by using multiple saturation pulses with alternating -shims. Using a database of maps, universal pulses are calculated that remove the necessity of time-consuming, subject-based pulse calculation during the measurement.
Methods:
PUSHUP was combined with a whole-brain three-dimensional-echo planar imaging (3D-EPI) readout. Two PUSHUP saturation modules were calculated by either applying whole-brain or cerebellum masks to the database maps. The saturation homogeneity and the group mean CEST amplitudes were calculated for different -correction methods and were compared to circular polarized (CP) saturation in five healthy volunteers using an eight-channel transmit coil at 7 Tesla.
Results:
In contrast to CP saturation, where accurate CEST maps were impossible to obtain in the cerebellum, even with extensive -correction, PUSHUP CEST maps were artifact-free throughout the whole brain. A 1-point retrospective -correction, that does not need repeated measurements, sufficiently removed the effect of residual saturation inhomogeneity.
Conclusion:
The presented method allows for homogeneous whole-brain CEST imaging at 7 Tesla without the need of a repetition-based -correction or online pulse calculation. With the fast 3D-EPI readout, whole-brain CEST imaging with 45 saturation offsets is possible at 1.6 mm resolution in under 4 min.