Related Experiment Video
Updated: Jun 12, 2025

Hollow Microneedle-based Sensor for Multiplexed Transdermal Electrochemical Sensing
Published on: June 1, 2012
Electrochemical sensing of vitamin B6 (pyridoxine) by adapted carbon paste electrode
Ayah Moustafa1, Soha A Abdel-Gawad2,3, M Shehata1
1Chemistry Department, Faculty of Science, Cairo University, Giza, 12613, Egypt.
Abstract:
The recent investigation targets to use adapted carbon paste (CP) with copper nanoparticles (CuNs) operating in a phosphate buffer (PBS) medium with a pH range of 5.0-8.0, to synthesize a novel, susceptible, and simple electrochemical sensor for the detection of one of the most important drugs, vitamin B6. Copper (Cu) is one of the most three common essential trace elements found in the bodies of both humans and animals, along with iron and zinc for all crucial physiological and biochemical functions. Its properties, which are assessed using a variety of methods including scanning electron microscopy (SEM), cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance spectroscopy (EIS), have also drawn a lot of attention recently. We considered the effects of pH, buffer, scan rate, interference, and calibration curve. The susceptible electrode's linear calibration curve encompassed concentration values between 8.88 and 1000.0 µM. The calculated limits of detection and quantification were 32.12 and 107.0 µM, respectively. Furthermore, this method was established in real human urine samples and drug validation which have been shown satisfactory results for vitamin B6 detection.
More Related Videos
10:48Electrochemical Preparation of Poly3,4-Ethylenedioxythiophene Layers on Gold Microelectrodes for Uric Acid-Sensing Applications
Published on: July 28, 2021
09:15Iridium Oxide-reduced Graphene Oxide Nanohybrid Thin Film Modified Screen-printed Electrodes as Disposable Electrochemical Paper Microfluidic pH Sensors
Published on: November 22, 2016
Related Concept Videos
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Potentiometry: Membrane Electrodes
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential...
Voltammetric Techniques: Pulse Voltammetry
Voltammetric Techniques: Cyclic Voltammetry