Comparison of the accommodative amplitude measured with and without the use of a specialised accommodative rule in
Hassan Hashemi1, Payam Nabovati2, Mehdi Khabazkhoob3
1Noor Research Center for Ophthalmic Epidemiology, Noor Eye Hospital, Tehran, Iran.
Insights
Measurements of accommodative amplitude (AoA) in children show poor agreement when using an accommodative rule versus without it. The accommodative rule resulted in a significantly lower mean AoA, indicating potential discrepancies in clinical assessments.
Area of Science:
- Ophthalmology
- Pediatric Optometry
- Vision Science
Background:
- Accurate measurement of accommodative amplitude (AoA) is crucial for assessing visual function in children.
- Standardized methods for measuring AoA are essential for reliable clinical practice and research.
- The use of specialized tools, such as accommodative rules, may influence measurement outcomes.
Purpose of the Study:
- To evaluate the agreement between accommodative amplitude (AoA) measurements in children obtained with and without a specialized accommodative rule.
- To compare the reliability and consistency of two distinct methods for assessing pediatric accommodative function.
Main Methods:
- 502 children (mean age 11.7 years) underwent optometric examinations, including visual acuity, refraction, and AoA measurement.
- AoA was measured monocularly using a -4 D lens, both with and without the Berens accommodative rule.
- Agreement was assessed using 95% limits of agreement (LoA) and interclass correlation coefficient (ICC).
Main Results:
- Mean AoA was 20.02±6.02 D with the rule and 22.46±6.32 D without the rule.
- The 95% LoA was -12.5 to 7.5 D, with an ICC of 0.67, indicating poor agreement.
- Agreement varied by age, sex, and refractive error, and decreased with higher AoA values.
Conclusions:
- There is poor and inconsistent agreement between AoA measurements made with and without an accommodative rule in children.
- The accommodative rule consistently yielded lower AoA values (mean difference of 2.5 D).
- Clinical decisions based on AoA measurements may differ depending on the method used.
Objective:
To determine the agreement between measurements of accommodative amplitude (AoA) in children using a specialised accommodative rule and measurments without it.
Methods:
A total of 502 children underwent optometric examinations, including the measurement of visual acuity, objective and subjective refraction. AoA measurements were done with and without the Berens accommodative rule. The measurements of AoA were conducted monocularly using a -4 D lens. A fixation stick containing English letters equivalent to 20/30 visual acuity and a long millimetre ruler was used to measure AoA without the accommodative rule. This measurement was performed by the two trained examiners. The agreement between these methods was reported by 95% limits of agreement (LoA) and interclass correlation coefficient (ICC).
Results:
The mean age of the participants was 11.7±1.3 years (range: 9-15 years) and 52.4% were male. The mean AoA with and without the accommodative rule was 20.02±6.02 D and 22.46±6.32 D, respectively. The 95% LoA between the two methods was -12.5 to 7.5 D, and the ICC was 0.67 (95% CI 0.63 to 0.70). The 95% LoA was narrower in higher age groups and males compared with females (18.92 vs 20.87). The 95% LoA was narrower in hyperopes (16.83 D) compared with emmetropes (18.37 D) and myopes (18.27 D). The agreement was not constant and decreased in higher values of AoA.
Conclusion:
There is a poor and non-constant agreement between the measurements of the AoA with and without the accommodative rule. The mean AoA was 2.5 D lower with using the accommodative rule.
More Related Videos
08:27Quantification of Oculomotor Responses and Accommodation Through Instrumentation and Analysis Toolboxes
Published on: March 3, 2023
06:19Comparison of Three Clinical Stereoscopic Methods for Measuring Binocular Visual Function During Amblyopic Treatment in Unilateral Amblyopia
Published on: September 27, 2024
Related Concept Videos
Ratio Level of Measurement
A set of data measured using the ratio scale takes care of the ratio problem and provides complete information. Ratio scale data are like interval scale data, except they have a zero point and ratios can be calculated. For...
Measures of Intelligence
Validity refers to how well a test measures what it claims to measure. An intelligence test should accurately assess intelligence rather than another characteristic, like anxiety. Criterion validity is one way to evaluate this; it...
Binet's Contribution to Measures of Intelligence