Related Experiment Video
Updated: Jun 12, 2025

Author Spotlight: An Efficient Methodology to Confidently Differentiate and Characterize Fentanyl Analogs
Published on: November 8, 2024
A broad-spectrum LC-MS/MS method for screening and quantification of 100 analytes in clinical and autopsy blood
Dimitra Florou1, Mathew Di Rago2, Amvrosios Orfanidis3
1Department of Forensic Medicine and Toxicology, Faculty of Medicine, School of Health Sciences, University of Ioannina, University Campus, Ioannina 45500, Greece.
Abstract:
Liquid chromatography coupled with mass spectrometry (LC-MS) has been tremendously used for screening purposes in forensic toxicology, because of their great adaptability and reasonable time/resource consumption. Herein, a fully validated method based on liquid-liquid extraction (LLE) in human whole blood, by a multiple reaction monitoring (MRM) analysis through LC-MS/MS, is described. The proposed method simultaneously detects 100 analytes (plus three deuterated internal standard compounds) belonging to many different classes, including drugs of abuse, prescription and over-the-counter drugs commonly involved in poisoning and medical malpractice cases in our territory, as well as certain new psychoactive substances (NPS) and toxic substances potentially associated with adverse effects. The optimised LLE employs one extraction step of 200 μL blood using 0.1 M HCl methyl-tert-butyl-ether (MTBE) (acidified with concentrated HCl) proved to be suitable for the extraction of basic and neutral substances; as a reconstitution solvent a mixture of 88:12v/v, 0.1 % formic acid in 10 mM aqueous ammonium acetate, pH 3.5: 0.1 % formic acid in acetonitrile was used, yielding satisfactory recoveries for all analytes. The method was sensitive, showing low LOD/ LOQ for all substances ranging from 0.01 to 5/ 0.05-20 ng/mL, respectively. Linearity ranged between 0.05-500 ng/mL (R2 = 0.9811-0.9995), and the inter- and intra-day precisions ranged between 3-15 % and 7-18 %, respectively. Accuracy was evaluated in terms of percentage recovery, lying within acceptable range. The matrix effect expressed as ion suppression/enhancement of each analyte was in the range ±25 % for all analytes. Post-preparative stability of analytes was higher than 85 %, while no carryover between runs was observed. The developed method has been successfully applied in routine toxicological analyses for the analysis of biological samples from clinical and autopsy cases.
More Related Videos
07:34Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS
Published on: March 14, 2013
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
MALDI-TOF Mass Spectrometry
Matrix-assisted laser desorption ionization (MALDI) is a commonly...