Is Averaging of Three Waveforms Sufficient to Generate a Truly Representative Value for Pulsed-Wave Doppler Measures
Ana Elizabeth Gomes de Melo Tavares Ferreira1, Jennifer Alphonse1, Alec William Welsh2
1School of Clinical Medicine, Discipline of Women's Health, Faculty of Medicine, University of New South Wales, Royal Hospital for Women, Sydney, Australia.
Objective:
We aimed to evaluate the physiological variation in common pulsed-wave Doppler (PWD) indices of impedance to determine the number of waveforms to be averaged to minimise variability to 5%.
Methods:
A single-centre, prospective, cross-sectional cohort study of uncomplicated singleton pregnancies at 20-37 week's gestation. From each patient 100 PWD waveforms were acquired including the umbilical artery (UA), middle cerebral artery (MCA) and uterine arteries (UtAs), with 30 waveforms acquired from the ductus venosus. Each waveform was individually measured using the machine's in-built software in automated mode. The variability was assessed using coefficient of variation. The number of waveforms to be averaged was calculated using the moving average and standard error of mean.
Results:
From a cohort of 200 pregnancies, a total of 189 were analysed. The pulsatility index (PI) demonstrated greater variability compared with the resistance index (RI) in all vessels studied. A minimum of 14 UA and MCA, and 13 UtA PWD waveforms were required to reduce PI variability to 5%, while only 2 RI waveforms were required for UA, 1 for MCA and 8 for UtAs.
Conclusion:
The variability shown across all PWD indices and between vessels means that PWD indices results should be interpreted cautiously and averaged over multiple waveforms. Consideration should be given to adoption of RI, as it showed greater stability than PI for maternal-fetal Doppler.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
RMS Value in AC Circuit
Mathematically, the RMS value of an AC waveform is the square root...
Average Power
Bode Plots Construction
Special considerations while measuring pulse