Related Experiment Video
Updated: Jun 12, 2025

In vitro Assessment of Aortic Regurgitation Using Four-Dimensional Flow Magnetic Resonance Imaging
Published on: February 25, 2022
Comparison of the imaging performance of time-of-flight MRA and ultrashort echo time MRA in flow diverters: A phantom
Toshiya Akatsu1,2, Akihiko Wada1, Michimasa Suzuki1
1Department of Radiology, Graduate School of Medicine, Juntendo University, Tokyo, Japan.
Objective:
Flow diverters (FD) are innovative treatments for wide-neck intracranial aneurysms. After-treatment verification of embolization and parent vessel patency is crucial. While evaluation using time-of-flight magnetic resonance angiography (TOF-MRA) is useful, it suffers from signal loss within the FD due to susceptibility effects. This study evaluates the usefulness of ultrashort echo time MRA (UTE-MRA) for after-FD assessment compared to TOF-MRA.
Methods:
Vascular phantom experiments were conducted using FDs (FRED®, Pipeline®, Surpass Streamline®). TOF-MRA and UTE-MRA were performed under steady (10, 30, 50 cm/s) and pulsatile (17-61 cm/s, mean 34 cm/s) flow conditions using a 3 T MRI system. As evaluation metrics, relative in-FD signal (RIS) was calculated by comparing the signal intensity inside the FD to that without the FD to assess signal retention, and FD luminal to background signal ratio (FD-LBR) was calculated by comparing the signal intensity inside the FD to that of the surrounding background to evaluate vessel visibility.
Results:
UTE-MRA showed higher FD-LBR values than TOF-MRA for all FDs (p < 0.01). For RIS, UTE-MRA was significantly higher for FRED® (p < 0.01), but different for other FDs except at 50 cm/s. FRED® exhibited the highest RIS and FD-LBR values under all conditions, followed by Pipeline® and Surpass Streamline®. Flow velocity changes resulted in minimal variations in RIS and FD-LBR values.
Conclusion:
UTE-MRA provides superior image quality for after-FD assessment, particularly in terms of FD-LBR, compared to TOF-MRA. Differences in FD materials and structures affect image quality. These findings suggest UTE-MRA's clinical utility in follow-up after-FD assessment.
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Magnetic Resonance Imaging

