Background:
To explore the impact of bladder size and shape on the accuracy of the formula method (V = 0.52 × d1 × d2 × d3) for bladder volume evaluation.
Methods:
Data was retrospectively collected from 220 patients without reportable bladder diseases. CT images were imported into 3D Slicer software to measure the bladder volume VA (reference standards). Bladder volume was also measured by the formula method VB = 0.52 × d1 × d2 × d3. Results of these two methods were compared based on bladder size and shape.
Results:
The bldder volume was 121.0 ± 83.6 mL with the formula method, compared with 128.5 ± 82.6 mL measured by 3D Slicer (P < 0.0001). Patients were divided into three groups based on bladder size, the mean percent deviations between the two methods were 18.8 ± 20.8%, 3.4 ± 12.9% and 4.6 ± 10.6%, respectively. According to the bladder shape, it can be divided into 5 types. For round and triangle shapes, there was no significant statistical difference in the results of the two methods. For bladder shapes with ellipse, rectangle and irregular shape, the volume evaluated by the formula method was statistically lower. Their deviations were 9.7 ± 17.5%, 12.9 ± 9.6% and 14.4 ± 21.2%, respectively.
Conclusion:
The accuracy of the formula method for estimating bladder volume is affected by bladder size and shape. Overall, the formula method tends to underestimate the bladder volume. The error of small-sized bladders is much greater than that of large-sized bladders. Furthermore, the formula method has high accuracy in measuring bladder volume with round and triangle shapes.
Related Concept Videos
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Accuracy, limits, and approximation
Accuracy is defined as the closeness of the measured value to the true or actual value. In engineering mechanics, repeated measurements are taken during theoretical or experimental analyses to ensure that the result is precise and accurate.
The accuracy of any solution is based on the...
Theorems of Pappus and Guldinus: Problem Solving
Pipe Flowrate Measurement
The orifice meter is a simple,...
Uncertainty in Measurement: Accuracy and Precision
Typical Model Studies