Related Experiment Video
Updated: Jun 12, 2025

Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
Assessment of ventricular electrical heterogeneity in left bundle branch pacing and left ventricular septal pacing by
Jesse H J Rijks1, Luuk Heckman2, Sjoerd Westra3
1Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University Medical Center+ (MUMC+), Maastricht, The Netherlands.
Introduction:
Left bundle branch area pacing (LBBAP) comprises pacing at the left ventricular septum (LVSP) or left bundle branch (LBBP). The aim of the present study was to investigate the differences in ventricular electrical heterogeneity between LVSP, LBBP, right ventricular pacing (RVP) and intrinsic conduction with different dyssynchrony measures using the ECG, vectorcardiograpy, ECG belt, and Ultrahigh frequency (UHF-)ECG.
Methods:
Thirty-seven patients with a pacemaker indication for bradycardia or cardiac resynchronization therapy underwent LBBAP implantation. ECG, vectorcardiogram, ECG belt and UHF-ECG signals were recorded during RVP, LVSP and LBBP, and intrinsic activation. QRS duration (QRSd) was measured from the ECG, QRS area was calculated from the vectorcardiogram, LV activation time (LVAT) and standard deviation of activation time (SDAT) from ECG belt and electrical dyssynchrony (e-DYS16) from UHF-ECG.
Results:
Both LVSP and LBBP significantly reduced ventricular electrical heterogeneity as compared to underlying LBBB and RV pacing in terms of QRS area (p < .001), SDAT (p < .001), LVAT (p < .001) and e-DYS16 (p < .001). QRSd was only reduced as compared to RV pacing(p < .001). QRS area was similar during LBBP and normal intrinsic conduction, e-DYS16 was similar during LVSP and normal intrinsic conduction, whereas SDAT was similar for LVSP, LBBP and normal intrinsic conduction. For all these variables there was no significant difference between LVSP and LBBP.
Conclusion:
Both LVSP and LBBP resulted in a more synchronous LV activation than LBBB and RVP. Especially LBBP resulted in levels of LV synchrony comparable to normal intrinsic conduction.
More Related Videos
08:19Electrophysiological Assessment of Murine Atria with High-Resolution Optical Mapping
Published on: February 22, 2018
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Related Concept Videos
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Electrophysiology of Normal Cardiac Rhythm