Related Experiment Video
Updated: Jun 12, 2025

Methodology for Establishing a Community-Wide Life Laboratory for Capturing Unobtrusive and Continuous Remote Activity and Health Data
Published on: July 27, 2018
User engagement with home blood pressure monitoring: a multinational cohort using real-world data collected with a
Jean-Simon Rech1,2,3, Nicolas Postel-Vinay4, Vincent Vercamer5
1Sorbonne Université, INSERM, Institut Pierre Louis d'Epidémiologie et de Santé Publique, UMR-S 1136, Réseau Sentinelles.
Objective:
Connected blood pressure (BP) monitors provide reliable data when used properly. Our objective was to analyse the engagement of real-world users with self-measurements.
Methods:
We included adult first-time users of a connected BP monitor from July 2019 to March 2021. They were categorized as persistent users if they continued to use the device between 311 and 400 days after inclusion. We defined a criterion to analyse the timing of self-measurements: at least 12 measurements performed within three consecutive days, at least once every 90 days. Persistent users were clustered by state sequence analysis according to the consistency of their BP monitor measurement timing with this criterion during 1 year of follow-up.
Results:
Among the 22 177 included users, 11 869 (54%) were persistent during the first year. Their use was consistent with the timing criterion 25% (median) of this time (first and third quartiles: 0%, 50%) and four patterns of use were identified by clustering: 5215 persistent users (44%) only performed occasional sparse measurements, 4054 (34%) complied at the start of follow-up up to eight cumulated months, 1113 (9%) complied at least once during later follow-up up to eight cumulated months, and the remaining 1487 (13%) complied nine or more cumulated months of follow-up.
Conclusion:
Although connected BP monitors can collect a high volume of data, the real-life timing of self-measurements is far from recommended schedules. We must promote the use of BP monitors as recommended by guidelines and/or learn to analyse more occasional and sparse measurements.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Pre-Procedural Guidelines for Assessing Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: