Related Experiment Video
Updated: Jun 12, 2025

Improving IV Insulin Administration in a Community Hospital
Published on: June 11, 2012
Automated Insulin Delivery for Young People with Type 1 Diabetes and Elevated A1c
Alisa Boucsein1, Yongwen Zhou1,2, Venus Michaels1
1Department of Women's and Children's Health, University of Otago, Dunedin, New Zealand.
Background:
Automated insulin delivery is the treatment of choice in adults with type 1 diabetes. Data are needed on the efficacy and safety of automated insulin delivery for children and youth with diabetes and elevated glycated hemoglobin levels.
Methods:
In this multicenter, open-label randomized controlled trial, we assigned patients with type 1 diabetes in a 1:1 ratio either to use an automated insulin delivery system (MiniMed 780G) or to receive usual diabetes care of multiple daily injections or non--automated pump therapy (control). The patients were children and youth (defined as 7 to 25 years of age) with elevated glycemia (glycated hemoglobin ≥8.5% with no upper limit). The primary outcome was the baseline-adjusted between-group difference in glycated hemoglobin at 13 weeks.
Results:
A total of 80 patients underwent randomization (37 to automated insulin delivery and 43 to control) and all patients completed the trial. At 13 weeks, the mean (±SD) glycated hemoglobin decreased from 10.5±1.9% to 8.1±1.8% in the automated insulin delivery group but remained relatively consistent in the control group, changing from 10.4±1.6% to 10.6±1.8% (baseline-adjusted between-group difference, -2.5 percentage points; 95% confidence interval [CI], -3.1 to -1.8; P<0.001). Patients in the automated insulin delivery group spent on average 8.4 hours more in the target glucose range of 70 to 180 mg/dl than those in the control group. One severe hypoglycemia event and two diabetic ketoacidosis events occurred in the control group, with no such events in the automated insulin delivery group.
Conclusions:
In this trial of 80 children and youth with elevated glycated hemoglobin, automated insulin delivery significantly reduced glycated hemoglobin compared with usual diabetes care, without resulting in severe hypoglycemia or diabetic ketoacidosis events. (Funded by Lions Clubs New Zealand District 202F and others; Australian New Zealand Clinical Trials Registry number, ACTRN12622001454763.).
Related Concept Videos
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Diabetes Mellitus: Overview and Type I Subtype
Type 1 diabetes is an autoimmune disease in which the immune system mistakenly attacks and destroys the insulin-producing beta cells in the pancreas. As a result, the body is unable to produce sufficient insulin, and individuals with...
Insulin Formulations: Types and Delivery
Short-acting insulins are divided into...
Diabetes: Management and Pharmacotherapy
Insulin remains the cornerstone of treatment for most patients with type 1 and many...
Diabetes Mellitus: Type 2 and Gestational
Carbohydrate Metabolism
Starch accounts for approximately 60% of the carbohydrates consumed by humans. Since amylase enzymes cannot function in the stomach's acidic environment, starch can only be digested in the mouth and small intestine. Simple sugars are found naturally in milk and fruits in...