Related Experiment Video
Updated: Jun 12, 2025

Applying X-ray Imaging Crystal Spectroscopy for Use as a High Temperature Plasma Diagnostic
Published on: August 25, 2016
Design of a diamond-based in-vessel soft x-ray detector for the SPARC tokamak
S Normile1, D Vezinet2, C Perks1
1Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA.
Abstract:
The in-vessel silicon diode arrays that are used for soft x-ray detection in many tokamaks are sensitive to neutron damage, making them unsuitable for burning plasma devices such as SPARC. In such a device, the silicon diodes would need to be placed far from the plasma-limiting their field of view-or an alternative detector could be used. Here, we present the design of a camera containing an array of chemical vapor deposition single-crystal diamonds, which will be placed in the upper and lower port plugs of the SPARC tokamak with a large enough view of the poloidal cross section to enable tomographic inversion. The camera design presented here is optimized to provide a wide field of view of the poloidal cross section. Simulated plasma conditions are used to estimate the x-ray signal that this detector array will receive and to fine-tune the camera placement within the tokamak.
More Related Videos
11:27Studying Soft-matter and Biological Systems over a Wide Length-scale from Nanometer and Micrometer Sizes at the Small-angle Neutron Diffractometer KWS-2
Published on: December 8, 2016
10:18Dynamic Pore-scale Reservoir-condition Imaging of Reaction in Carbonates Using Synchrotron Fast Tomography
Published on: February 21, 2017