Related Experiment Video For MRI
Updated: Jun 12, 2025

Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
Diagnostic Imaging Performance of Dual-Energy Computed Tomography Compared with Conventional Computed Tomography and
Saki Shibuki1, Tsukasa Saida2, Kensaku Mori2
1Department of Radiology, University of Tsukuba Hospital, Tsukuba, Ibaraki, Japan.
Abstract:
Objective This article evaluates the ability of low-energy (40 keV) virtual monoenergetic images (VMIs) in the local diagnosis of cervical cancer compared with that of conventional computed tomography (C-CT) and magnetic resonance imaging (MRI), using clinicopathologic staging as a reference. Methods This prospective study included 33 patients with pathologically confirmed cervical cancer who underwent dual-energy CT and MRI between 2021 and 2022. The contrast-to-noise ratio (CNR) of the tumor-to-myometrium was compared between C-CT and VMI. Additionally, sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) for each local diagnostic parameter were compared between C-CT, VMI, and MRI. Interradiologist agreement was also assessed. Results The mean CNR was significantly higher on VMI ( p = 0.002). No significant difference in AUC was found between C-CT and VMI for all local diagnostic parameters, and the specificity of VMI was often significantly less than that of MRI. For parametrial invasion, mean sensitivity, specificity, and AUC for C-CT, VMI, and MRI were 0.81, 0.99, 0.93; 0.64, 0.35, 0.79; and 0.73, 0.67, 0.86, respectively, and MRI had significantly higher specificity and AUC than that of VMI ( p = 0.013 and 0.008, respectively). Interradiologist agreement was higher for VMI than C-CT and for MRI than VMI. Conclusion The CNR of VMI was significantly higher than C-CT and interradiologist agreement was better than with C-CT; however, the overall diagnostic performance of VMI did not significantly differ from C-CT and was inferior to MRI. VMI was characterized by low specificity, which should be understood and used for reading.
More Related Videos
10:28Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
15:48Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Magnetic Resonance Imaging
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
X-ray Imaging