Related Experiment Video
Updated: Jun 12, 2025

Electrocardiogram Recordings in Anesthetized Mice using Lead II
Published on: June 20, 2020
The Best ECG Lead for Predicting the Risk of Drug-Induced Torsade De Pointes Using Corrected QT Interval: A
Tharathorn Raicharoen1, Suphaphorn Vassasunthorn1, Rittirak Othong1
1Department of Emergency Medicine, Faculty of Medicine Vajira Hospital, Navamindradhiraj University, Dusit, Bangkok, Thailand, 10300.
Introduction:
Torsade de pointes (TdP) is a deadly complication from drug-induced QT prolongation. Each of the 12 lead of an electrocardiogram (ECG) has a different length of QT interval, and thus might have a different performance in TdP prediction. This study aimed to determine the best ECG lead or set of leads in this regard.
Methods:
This is a comparative prognostic accuracy study using a two-gate data gathering design. The population in this study was from two sources, a case group (Patients who had drug-induced TdP, which were identified through a systematic Medline search) and a control group (those who overdosed on QT-prolonging drugs, which included patients who were under the consultation of Medical Toxicology Services). The areas under the receiver operating characteristic curve (AUROC) of heart rate-corrected QT (QTc) in each single ECG lead and of a mean/median QTc from a set of ECG leads (17 index test) in predicting the risk of TdP were calculated and compared with each other, trying to find the best lead for this propose. QTc Interval measurements were done by four investigators (Interrater reliabilities 0.95).
Results:
Finally, we included 136 and 148 ECGs from TdP cases and controls, respectively. V3 lead had the highest frequency of longest QTc interval, among the leads. The lead having the longest QTc yielded the greatest AUROC in predicting TdP regardless of QT correction formulas (QTcFRA=0.9915, QTcRTH=0.9893, QTcBZT=0.9904). The mean QTc of 3 leads (lead II, plus any two of leads V2-V4), and a median QTc of 6 leads (I, II, aVF, V2, V4, V6) provided similar overall performance for TdP prediction (regardless of the type of QTc formula).
Conclusion:
The longest QTc provided the greatest AUROC in predicting drug-induced TdP, however, the longest QTc is not located in a fixed individual lead in any patient. A less time-consuming method with comparable performance to that of the longest QTc was to use a mean QTc from 3 leads (lead II, plus any two of leads V2-V4). The potential clinical impact of this finding needs to be verified in a prospective cohort study.
More Related Videos
08:28Methods for ECG Evaluation of Indicators of Cardiac Risk, and Susceptibility to Aconitine-induced Arrhythmias in Rats Following Status Epilepticus
Published on: April 5, 2011
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
Related Concept Videos
Antiarrhythmic Drugs: Class III Agents as Potassium Channel Blockers
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Antiarrhythmic Drugs: Class I Agents as Sodium Channel Blockers
Class 1A Antiarrhythmic Drugs: These drugs work by moderately blocking sodium channels,...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Antiarrhythmic Drugs: Class IV Agents as Calcium Channel Blockers
Verapamil, a calcium channel blocker, inhibits calcium movement across myocardial cell membranes and vascular smooth muscle. This results in the dilation of coronary and...