Niray Bhakta1, Alexander S Kaplitz1, Destini Black1
1Department of Chemistry and Biochemistry, The University of Texas at Arlington, Arlington, Texas, USA.
Abstract:
A commercially available dielectric barrier discharge ionization (DBDI) source was tested with supercritical fluid chromatography-mass spectrometry (SFC-MS). The compound mixture investigated comprised caffeine, theobromine, theophylline, uracil, testosterone, and pyrene, diluted in methanol. Dynamic response ranges were evaluated with multiple injections at different concentrations. Precision studies demonstrated the robustness and sensitivity of the ionization source across a concentration range of 10-1000 ng/mL. Results from this experiment showed linear regression of 0.99 or greater for all analytes tested over the range with a relative standard deviation (RSD) of less than 10% down to 10 ng/mL for all analytes except theobromine, which had an RSD of less than 10% down to 25 ng/mL. Notably, this study marks the first investigation of sensitivity for coupling a commercial DBDI source with SFC; a limit of detection less than 1 ng/mL was achieved for all compounds. This study demonstrates chromatographic separation by SFC and MS analysis for compounds that ionize poorly using traditional atmospheric pressure ionization, such as polycyclic aromatic hydrocarbons. Combining SFC with the DBDI source opens promising avenues for analyzing compounds that were previously challenging to characterize with standard atmospheric pressure ionization techniques.
More Related Videos
10:22In Situ SIMS and IR Spectroscopy of Well-defined Surfaces Prepared by Soft Landing of Mass-selected Ions
Published on: June 16, 2014
07:53Analysis of Complex Molecules and Their Reactions on Surfaces by Means of Cluster-Induced Desorption/Ionization Mass Spectrometry
Published on: March 1, 2020
Related Concept Videos
Chemical Ionization (CI) Mass Spectrometry
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Mass Spectrometry: Overview
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...