Related Experiment Video
Updated: Jun 12, 2025

Leaf Spray Mass Spectrometry: A Rapid Ambient Ionization Technique to Directly Assess Metabolites from Plant Tissues
Published on: June 21, 2018
Magnetic particle spray mass spectrometry for the determination of beta-blockers in plasma samples
Elizângela Maria de Castilho Alves Morais1, Tássia Venga Mendes1, Estela Domingos Arnoni1
1Laboratory of Toxicant and Drug Analyses, Faculty of Pharmaceutical Sciences, Federal University of Alfenas, Alfenas, MG, 37130-001, Brazil.
Abstract:
Magnetic particle spray mass spectrometry (MPS-MS), an innovative ambient ionization technique proposed by our research group, was employed to determine beta-blockers in human plasma samples. A dispersive solid phase extraction of atenolol, metoprolol, labetalol, propranolol, nadolol, and pindolol was carried out using magnetic molecularly imprinted polymer (M-MIP) particles that were attached to the tip of a metal probe, which was placed in the mass spectrometer inlet. A solvent (1% formic acid in methanol) was dispensed on the particles, and the Taylor cone was formed around them (in high voltage). The analytes were desorbed/ionized and determined by a triple quadrupole mass spectrometer. M-MIP was synthesized with oxprenolol as a pseudo-template, demonstrating good selectivity to beta-blockers compared with no-analog molecules, with an adsorption process occurring in monolayers, according to isotherm studies. Kinetic experiments indicated chemisorption as the predominant M-MIP/analyte interaction. The analytical curves were linear (R2 > 0.98), and the limit of quantification was 3 µg L-1 for all the analytes. Limits of detection ranged from 0.64 to 2.41 µg L-1. Precisions (relative standard deviation) and accuracies (relative error) ranged from 3.95 to 21.20% and -17.05 to 18.93%, respectively. MPS-MS proved to be a simple, sensitive, and advantageous technique compared with conventional approaches. The analyses were fast, requiring no chromatographic separation and without ionic suppression. The method is aligned with green chemistry principles, requiring minimal sample, solvent, and sorbent amounts. MPS-MS successfully integrates sample preparation and ambient ionization mass spectrometry and holds great potential for application with other sorbents, samples, and analytes.
More Related Videos
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Mass Spectrometers
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Mass Spectrometry: Overview

