Related Experiment Video
Updated: Jun 12, 2025

Drug-Induced Sleep Endoscopy DISE with Target Controlled Infusion TCI and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
Relationship of Modified Sleep Apnea Severity Index and HGNS Efficacy and Adherence in OSA Patients
Praneet C Kaki1, Nicole Molin2, Jennifer A Goldfarb1
1Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, Pennsylvania, U.S.A.
Objectives:
Hypoglossal nerve stimulation (HGNS) is a treatment option for patients with CPAP-intolerant (CPAPi) obstructive sleep apnea (OSA). The modified sleep apnea severity index (mSASI) combines patient anatomy, weight, sleep study metrics, and symptoms into a composite index ranging from 1 (least severe) to 3 (most severe). Prior studies have associated mSASI with quality of life, CPAP adherence, and hypertension, but its utility in CPAPi patients is unknown. We evaluate the relationship between mSASI, HGNS efficacy, and adherence.
Methods:
Retrospective cohort study of consecutive CPAPi OSA patients who underwent HGNS from 2014 to 2023. Patients were included if data were available to calculate preoperative mSASI and postoperative HGNS adherence/efficacy. Kruskal-Wallis rank-sum, Fisher's exact, and Chi-squared tests were performed.
Results:
264 patients were included (mean age = 61.3 years, 95% White, 66% Male). Preoperatively, 168 (64%) patients had mSASI of 1, 81 (31%) mSASI = 2, and 15 (5.7%) mSASI = 3. At 3 months post-op, patients with baseline mSASI of 1, 2, and 3 showed 6.72, 6.39, and 5.88 hours/night of device usage (p = 0.4). This pattern persisted, although showing no significance, at 6 months, 12 months, and most recent follow-up. There were similar reductions in Epworth Sleepiness Scale (ESS) across cohorts, with the mSASI3 group having the highest ESS postoperatively (p < 0.01). Sher15 response was similar between cohorts (mSASI1 = 52%, mSASI2 = 40%, mSASI3 = 25%, p = 0.2).
Conclusion:
Preoperative mSASI was not significantly correlated with HGNS adherence. Higher baseline mSASI was associated with greater postoperative daytime sleepiness. Further study is needed to evaluate mSASI as a tool within this population.
Level Of Evidence:
3 Laryngoscope, 135:1212-1217, 2025.
Related Concept Videos
Sleep Apnea
The condition is more prevalent among...
Heart Failure VI: Adjunct Therapies
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...