Related Experiment Video
Updated: Jun 12, 2025

Swin-PSAxialNet: An Efficient Multi-Organ Segmentation Technique
Published on: July 5, 2024
USCT-UNet: Rethinking the Semantic Gap in U-Net Network From U-Shaped Skip Connections With Multichannel Fusion
Abstract:
Medical image segmentation is a crucial component of computer-aided clinical diagnosis, with state-of-the-art models often being variants of U-Net. Despite their success, these models' skip connections introduce an unnecessary semantic gap between the encoder and decoder, which hinders their ability to achieve the high precision required for clinical applications. Awareness of this semantic gap and its detrimental influences have increased over time. However, a quantitative understanding of how this semantic gap compromises accuracy and reliability remains lacking, emphasizing the need for effective mitigation strategies. In response, we present the first quantitative evaluation of the semantic gap between corresponding layers of U-Net and identify two key characteristics: 1) The direct skip connection (DSC) exhibits a semantic gap that negatively impacts models' performance; 2) The magnitude of the semantic gap varies across different layers. Based on these findings, we re-examine this issue through the lens of skip connections. We introduce a Multichannel Fusion Transformer (MCFT) and propose a novel USCT-UNet architecture, which incorporates U-shaped skip connections (USC) to replace DSC, allocates varying numbers of MCFT blocks based on the semantic gap magnitude at different layers, and employs a spatial channel cross-attention (SCCA) module to facilitate the fusion of features between the decoder and USC. We evaluate USCT-UNet on four challenging datasets, and the results demonstrate that it effectively eliminates the semantic gap. Compared to using DSC, our USC and SCCA strategies achieve maximum improvements of 4.79% in the Dice coefficient, 5.70% in mean intersection over union (MIoU), and 3.26 in Hausdorff distance.
Related Concept Videos
Transformers in Distribution System
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Types Of Transformers
If the ratio of the number of turns in the secondary winding to that of the primary winding is greater than one, then the transformer is said to be a step-up transformer. In a step-up transformer, the voltage at the secondary winding is greater than the voltage applied at the primary winding.
However, if this ratio is less than one, the transformer is said to be a step-down...
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
The Ideal Transformer
Ampere's Law forms the basis of understanding the magnetic field within the transformer. It states that the integral of the magnetic field intensity's...
Equivalent Circuits for Practical Transformers
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
Transformers with Off-Nominal Turns Ratios