THz-TDS transflection measurements as a process analyser for tablet mass
Moritz Anuschek1, Thomas Kvistgaard Vilhelmsen2, J Axel Zeitler3
1Department of Pharmacy, University of Copenhagen, Copenhagen, Denmark; Novo Nordisk A/S, ET Oral Product Development, Måløv, Denmark.
International Journal of Pharmaceutics
|September 26, 2024
Summary
Terahertz time-domain spectroscopy (THz-TDS) offers a novel, rapid method for measuring tablet mass, crucial for drug product quality. This technique enables real-time monitoring of tablet weight and height during manufacturing.
Area of Science:
- Pharmaceutical Technology
- Analytical Chemistry
- Spectroscopy
Background:
- Tablet content uniformity is critical for drug efficacy and market release.
- Current methods for controlling tablet mass lack robustness, sensitivity, and speed.
- Process analytical technology (PAT) is essential for real-time pharmaceutical manufacturing control.
Purpose of the Study:
- To investigate terahertz time-domain spectroscopy (THz-TDS) as a process analytical tool for tablet mass measurement.
- To assess the feasibility of using THz-TDS for in-line monitoring of tablet physical attributes.
- To explore the potential of THz-TDS for simultaneous measurement of tablet mass and height.
Main Methods:
- Utilized terahertz time-domain spectroscopy (THz-TDS) in a reflection setup to analyze tablets.
- Measured the time delay of frontside reflection and backside transflection signals.
- Correlated the time delay of the backside transflection with tablet mass.
Main Results:
- An increase in tablet mass directly correlated with an increased time delay of the backside transflection signal.
- Achieved root mean squared errors of approximately 1 mg for tablet mass determination.
- Demonstrated the potential for high acquisition rates (50 Hz) for rapid analysis.
- Showcased simultaneous measurement of tablet height using frontside reflection.
Conclusions:
- THz-TDS is a viable and sensitive method for indirect tablet mass measurement.
- The technique enables in-line monitoring of tablet mass and height, supporting content uniformity strategies.
- This methodology facilitates real-time control of the tablet compression process based on physical attributes.
Related Concept Videos
Tandem Mass Spectrometry
927
Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and signal-to-noise ratio for the analyte. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
927
Mass Analyzers: Common Types
579
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
579
Mass Analyzers: Overview
615
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
615