A Protocol of Manual Tests to Measure Sensation and Pain in Humans
Published on: December 19, 2016
Reliability and validity of the pressure algometer in predicting gynecological surgery pain
Qian Yin1, Di Wang2, Xiao-Hong Chen3
1Department of Anesthesiology, Affiliated Hospital of Nantong University, Nantong, China.
Objective:
The purpose of this study was to determine the reliability and validity of the pressure algometer in predicting gynecological surgery pain. We looked into the predictive value of preoperative pain sensitivity to gynecological pain and the relationship between preoperative pressure pain threshold (PPT), pressure pain tolerance (PTO), and postoperative pain outcomes.
Methods:
Reliability test: We recruited 60 volunteers at Nantong University. For three consecutive days, two examiners measured the pain sensitivity of each participant using a pressure algometer. Its test-retest and intra-rater reliability were assessed using the intraclass correlation coefficient (ICC). Validity test: We selected patients who underwent gynecological surgery in a hospital for the validity test. Before surgery, we assessed the patient's pain sensitivity to various stimuli. To determine the relationship between preoperative pain sensitivity and postoperative pain, we collected postoperative Numerical Rating Scale (NRS) and sufentanil consumption data.
Results:
The algometer revealed a high test-retest and intra-rater reliability. According to the calculation of Youden's index, there was a 73.1% chance of patients with moderate to severe postoperative pain having a PTO <6.22 N, and patients with PTO <6.22 N had an 87.5% probability of moderate to severe postoperative pain.
Conclusions:
The pressure algometer has a high degree of accuracy in measuring the PPT and PTO of normal healthy individuals, making it a reliable tool for quantifying pain sensitivity. PTO can be used to predict the occurrence of moderate to severe postoperative pain.
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.