Economic Impact of Ambulatory Blood Pressure Monitoring Compared With Clinical Blood Pressure Monitoring: A
Michelle A Hayek1,2, Alejandro Catacora2,3, Mark A Lawley1,2
1Department of Industrial and Systems Engineering, Texas A&M University, College Station, TX, USA.
Background:
Ambulatory blood pressure monitoring (ABPM) is considered the gold standard for proper diagnosis of hypertension. Yet, access to ABPM in the U.S. is limited, and the extent of coverage by commercial health plans remains uncertain, potentially limiting access to ABPM among commercially insured patients.
Objective:
This study aims to assess the net cost impact of using ABPM in comparison to clinical blood pressure monitoring (CBPM) in the U.S. over a 5-year time period.
Design Methods:
Using a Markov Model, we estimate the 5-year cumulative cost impact of using ABPM to confirm a prior diagnosis of primary hypertension using CBPM to avoid treatment for white-coat hypertension (WCH) in a hypothetical cohort of 1000 patients from a U.S. healthcare system perspective. The probability and cost inputs for the model were derived from available literature. Base-case model parameters were varied to account for different scenarios.
Results:
Base-case results indicate using ABPM instead of CBPM over 5 years saves a total of $348,028, reflecting an average per-person-per-year (PPPY) cost saving of $70. In sensitivity analyses, almost all cases reveal ABPM as a cost-saving approach compared to CBPM, with cost savings reaching up to $228 PPPY in the highest hypertension treatment cost model. Regression results reveal that ABPM was cost-saving compared to CBPM if ABPM annual payment rates are $100 or less and annual hypertension treatment costs are ⩾$300.
Conclusion:
The potential cost-savings of using ABPM instead of CBPM found in our simulation model underscores the need for confirmatory research using real-world data to support increased use of ABPM as the standard diagnostic approach for hypertension.
More Related Videos
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Hypertension III: Clinical Manifestations and Diagnostic Studies
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure