Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
Published on: July 29, 2013
Two-Dimensional Mammography Imaging Techniques for Screening Women with Silicone Breast Implants: A Pilot Phantom
Isabelle Fitton1, Virginia Tsapaki2, Jonathan Zerbib1
1Department of Radiology, AP-HP, Hôpital Européen Georges Pompidou, 75015 Paris, France.
Abstract:
This study aimed to evaluate the impact of three two-dimensional (2D) mammographic acquisition techniques on image quality and radiation dose in the presence of silicone breast implants (BIs). Then, we propose and validate a new International Atomic Energy Agency (IAEA) phantom to reproduce these techniques. Images were acquired on a single Hologic Selenia Dimensions® unit. The mammography of the left breast of a single clinical case was included. Three methods of image acquisition were identified. They were based on misused, recommended, and reference settings. In the clinical case, image criteria scoring and the signal-to-noise ratio on breast tissue (SNRBT) were determined for two 2D projections and compared between the three techniques. The phantom study first compared the reference and misused settings by varying the AEC sensor position and, second, the recommended settings with a reduced current-time product (mAs) setting that was 13% lower. The signal-difference-to-noise ratio (SDNR) and detectability indexes at 0.1 mm (d' 0.1 mm) and 0.25 mm (d' 0.25 mm) were automatically quantified using ATIA software. Average glandular dose (AGD) values were collected for each acquisition. A statistical analysis was performed using Kruskal-Wallis and corrected Dunn tests (p < 0.05). The SNRBT was 2.6 times lower and the AGD was -18% lower with the reference settings compared to the recommended settings. The SNRBT values increased by +98% with the misused compared to the recommended settings. The AGD increased by +79% with the misused settings versus the recommended settings. The median values of the reference settings were 5.8 (IQR 5.7-5.9), 1.2 (IQR 0.0), 7.0 (IQR 6.8-7.2) and 1.2 (IQR 0.0) mGy and were significantly lower than those of the misused settings (p < 0.03): 7.9 (IQR 6.1-9.7), 1.6 (IQR 1.3-1.9), 9.2 (IQR 7.5-10.9) and 2.2 (IQR 1.4-3.0) mGy for the SDNR, d' 0.1 mm, d' 0.25 mm and the AGD, respectively. A comparison of the recommended and reduced settings showed a reduction of -6.1 ± 0.6% (p = 0.83), -7.7 ± 0.0% (p = 0.18), -6.4 ± 0.6% (p = 0.19) and -13.3 ± 1.1% (p = 0.53) for the SDNR, d' 0.1 mm, d' 0.25 mm and the AGD, respectively. This study showed that the IAEA phantom could be used to reproduce the three techniques for acquiring 2D mammography images in the presence of breast implants for raising awareness and for educational purposes. It could also be used to evaluate and optimize the manufacturer's recommended settings.
More Related Videos
11:05Tissue-simulating Phantoms for Assessing Potential Near-infrared Fluorescence Imaging Applications in Breast Cancer Surgery
Published on: September 19, 2014
15:48Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies I: Kidney, Ureter, and Bladder Studies
Imaging Studies II: Ultrasonography
Imaging Studies III: Computed Tomography
Imaging Studies VI: Voiding Cystourethrography and Cystography