High-Intensity focused ultrasound linear array and system for dermatology treatment
Juhwan Kim1, Jinwoo Kim1, Duk Kyu Lee2
1Department of Electrical Engineering and Computer Science, Daegu Gyeongbuk Institute of Science and Technology (DGIST), Daegu, Korea.
Abstract:
Dermatological lesions are typically located just a few millimeters below the surface of the skin, which constrains the efficacy of optical-based therapeutic methods such as photothermal and photodynamic therapy due to limited therapeutic depth caused by optical scattering. As an alternative, high-intensity focused ultrasound (HIFU) has been explored for its potential to treat a variety of dermatological conditions because it offers greater flexibility in terms of treatment depth. Since dermatological lesions have a small thickness ranging from 1.5 to 2.0 mm, high-frequency ultrasound (3-10 MHz or higher) is preferred as the focal area is proportional to the operating frequency. However, due to the difficulty in fabricating HIFU array transducers at this frequency range, the majority of HIFU treatments for dermatology rely on single element transducers. Despite the advantages of HIFU, single-element-based HIFU systems are limited in prevalent use for dermatology treatment due to their fixed focal length and mechanical movement for treatment, which can be time-consuming and unsuitable for treating multiple lesions. To address this, we present a newly developed HIFU linear array and 128-channel driving electronics specifically designed for dermatology treatment. This array consists of 128 elements, has a center frequency of 3.7 MHz, an elevation focal length of 28 mm, and an F-number of 1.27 in the elevation direction. The array has a footprint of 71.6 mm by 22 mm. Experiments using a tissue-mimicking phantom have demonstrated that the HIFU linear array and system are capable of transmitting sufficient ultrasound energy to create coagulation inside the phantom.
More Related Videos
08:08Evaluating Targeting Accuracy in the Focal Plane for an Ultrasound-guided High-intensity Focused Ultrasound Phased-array System
Published on: March 6, 2019
07:38Real-time Monitoring of High Intensity Focused Ultrasound HIFU Ablation of In Vitro Canine Livers Using Harmonic Motion Imaging for Focused Ultrasound HMIFU
Published on: November 3, 2015
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasonography
During an ultrasonography procedure, a handheld device called...