Related Experiment Video
Updated: Jul 6, 2026

Measurement of Dynamic Scapular Kinematics Using an Acromion Marker Cluster to Minimize Skin Movement Artifact
Published on: February 10, 2015
The Development of a Yolov8-Based Model for the Measurement of Critical Shoulder Angle (CSA), Lateral Acromion Angle
1Department of Electrical and Electronics Engineering, Kahramanmaras Sutcu Imam University, 46050 Onikişubat, Turkey.
Abstract:
Background: The accurate and effective evaluation of parameters such as critical shoulder angle, lateral acromion angle, and acromion index from shoulder X-ray images is crucial for identifying pathological changes and assessing disease risk in the shoulder joint. Methods: In this study, a YOLOv8-based model was developed to automatically measure these three parameters together, contributing to the existing literature. Initially, YOLOv8 was used to segment the acromion, glenoid, and humerus regions, after which the CSA, LAA angles, and AI between these regions were calculated. The MURA dataset was employed in this study. Results: Segmentation performance was evaluated with the Dice and Jaccard similarity indices, both exceeding 0.9. Statistical analyses of the measurement performance, including Pearson correlation coefficient, RMSE, and ICC values demonstrated that the proposed model exhibits high consistency and similarity with manual measurements. Conclusions: The results indicate that automatic measurement methods align with manual measurements with high accuracy and offer an effective alternative for clinical applications. This study provides valuable insights for the early diagnosis and management of shoulder diseases and makes a significant contribution to existing measurement methods.
More Related Videos
07:12Semiautomated Longitudinal Microcomputed Tomography-based Quantitative Structural Analysis of a Nude Rat Osteoporosis-related Vertebral Fracture Model
Published on: September 28, 2017
06:09Measuring 3D In-vivo Shoulder Kinematics using Biplanar Videoradiography
Published on: March 12, 2021
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Muscles of the Shoulder
Anterior Thoracic Muscles
The anterior thoracic muscles include the serratus anterior, subclavius, and...
Eccentric Axial Loading in a Plane of Symmetry