Related Experiment Video
Updated: Jun 11, 2025

Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
Experimental and Numerical Study on Lightweight-Foamed-Concrete-Filled Widened Embankment of High-Speed Railway
Didi Hao1,2, Changqing Miao1,2, Shisheng Fang3
1Key Laboratory of Concrete and Prestressed Concrete Structures of Ministry of Education, Southeast University, Nanjing 211189, China.
Abstract:
To study the performance of lightweight foamed concrete (LWFC) in widened embankments of high-speed railways, this study first conducted numerous strength, permeability, and water immersion tests to investigate the mechanical properties and water resistance of LWFC with designed dry densities of 550, 600, and 650 kg/m3. Secondly, a field test was performed to analyze the behavior of the deformation and the internal pressure within the LWFC-filled portions. Furthermore, a parametric study via numerical modeling was performed to investigate the effects of four key factors on the performance of the LWFC-filled, widened embankments. Results showed that LWFC possesses adequate bearing capacity and impermeability to meet high-speed railway embankment widening requirements. However, water seepage reduces LWFC strength. The additional pressure from LWFC filling increases initially but then decreases once dehydration occurs. The settlement induced by LWFC accounted for 71% of the total filling height, which is only 37.5% of the total settlement after construction. The parametric study results show that the maximum settlement of widened and existing portions induced by LWFC was 46.3-49.6% and 48.3-53.2% of those induced by traditional fillers due to the LWFC's lower density as well as their better self-supporting ability. Making an appropriate reduction in the thickness of the retain wall installed against the LWFC-filled widened embankment of the high-speed railway generates a few variations in the lateral deformation of the wall. Furthermore, the effects of the pile offset on the deformation of the LWFC-filled embankment were more sensitive compared to the diameter of the piles.
More Related Videos
Related Concept Videos
Effects of Air-entrainment in Concrete
Design Example: Maintaining Level of an Embankment
Fiber Reinforced Concrete
Shrinkage in Concrete
When concrete is still in its plastic state, it can undergo a decrease in volume by about 1% of its absolute volume. This decrease is known as plastic shrinkage. It arises either...
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Design Example: Managing Concrete Workability

