Automated Breast Ultrasound for Evaluating Response to Neoadjuvant Therapy: A Comparison with Magnetic Resonance
Michele Telegrafo1, Stefania Luigia Stucci1, Angela Gurrado2
1Breast Care Unit, University Hospital Consortium Policlinico of Bari, Piazza Giulio Cesare 11, 70124 Bari, Italy.
Abstract:
Background: Neoadjuvant chemotherapy (NAC) is currently used for treating breast cancer in selected cases. Our study aims to evaluate the role of automated breast ultrasound (ABUS) in the assessment of response to NAC and compare the ABUS results with MRI. Methods: A total of 52 consecutive patients were included in this study. ABUS and MRI sensitivity (SE), specificity (SP), diagnostic accuracy (DA), positive predictive value (PPV), and negative predictive value (NPV) were calculated and represented using Area Under ROC Curve (ROC) analysis, searching for any significant difference (p < 0.05). The McNemar test was used searching for any significant difference in terms of sensitivity by comparing the ABUS and MRI results. The inter-observer agreement between the readers in evaluating the response to NAC for both MRI and ABUS was calculated using Cohen's kappa k coefficient. Results: A total of 35 cases of complete response and 17 cases of persistent disease were found. MRI showed SE, SP, DA, PPV, and NPV values of 100%, 88%, 92%, 81%, and 100%, respectively, with an AUC value of 0.943 (p < 0.0001). ABUS showed SE, SP, DA, PPV, and NPV values of 88%, 94%, 92%, 89%, and 94%, respectively, with an AUC of 0.913 (p < 0.0001). The McNemar test revealed no significant difference (p = 0.1250). The inter-observer agreement between the two readers in evaluating the response to NAC for MRI and ABUS was, respectively, 0.88 and 0.89. Conclusions: Automatic breast ultrasound represents a new accurate, tri-dimensional and operator-independent tool for evaluating patients referred to NAC.
Related Concept Videos
Imaging Studies IV: Magnetic Resonance Imaging
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...


