Abstract:
Two-dimensional gas chromatography (GC × GC) and two-dimensional liquid chromatography (LC × LC) are nowadays widely used in academia and industry due to their high separation power. However, as far as we know, the complementarity of these two techniques has not yet been thoroughly studied based on the analysis of the same sample. Therefore, this was undertaken here by analysing the liquid fraction obtained after depolymerising a natural waste - lignin - with GC × GC and off-line comprehensive LC × SFC (SFC: supercritical fluid chromatography). Using complementary techniques is also important for lignin valorisation, as thorough structural characterisation of the depolymerised product can aid with developing and improving valorisation processes. For the tentative identification, NIST library was used for GC × GC-MS results and MS-DIAL together with SIRIUS for LC × SFC-MS/MS data. This allowed to study which compounds are detectable with the different 2D methods but also to discuss the limitations of the data analysis processes. The previous knowledge that LC techniques are more suitable than GC × GC for the analysis of larger oligomers and other low volatility compounds was confirmed; however, it was seen that GC × GC enabled the analysis of smaller compounds, such as aliphatic alcohols and saturated compounds. Overall, the study demonstrates the complementarity of the two techniques but also draws attention to the different detectable compound groups and classifications that the two techniques can provide.
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...