Related Experiment Video
Updated: Jun 11, 2025

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
Published on: December 18, 2016
Reliability, reproducibility, and potential pitfalls of the O-RADS scoring with non-dynamic MRI
Gulsum Kılıçkap1, Betül Akdal Dölek1, Serhat Kaya2
1Radiology Department, T.C. Ministry of Health, Ankara Bilkent City Hospital, Ankara, Türkiye.
Background:
The O-RADS scoring has been proposed to standardize the reporting of adnexal lesions using magnetic resonance imaging (MRI).
Purpose:
To assess intra- and inter-observer agreement of the O-RADS scoring using non-dynamic MRI and its agreement with pathologic diagnosis, and to provide the pitfalls in the scoring based on discordant ratings.
Material And Methods:
Adnexal lesions that were diagnosed using non-dynamic MRI at two centers were scored using O-RADS. Intra- and inter-observer agreements were assessed using kappa statistics. Cross-tabulations were made for intra- and inter-observer ratings and for O-RADS scores and pathological findings.
Results:
Intra- and inter-observer agreements were assessed for 404 lesions in 339 patients who were admitted to center 1. Intra-observer agreement was almost perfect (97.8%, kappa = 0.963) and inter-observer agreement was substantial (83.2%, kappa = 0.730). The combined data from center 1 and center 2 included 496 patients; of them, 295 (59.5%) were operated. There was no borderline or malignant pathology for the lesions with O-RADS 1 or 2. Of those with an O-RADS score of 3, 3 (4.1%) lesions were borderline and none were malignant. The O-RADS scoring in discriminating borderline/malignant lesions from benign lesions was outstanding (area under the ROC curve 0.950, 95% CI = 0.923-0.971). Sensitivity, specificity, positive, and negative predictive values of O-RADS 4/5 lesions for borderline/malignant lesions were 96.2%, 87.1%, 72.8%, and 98.4%, respectively.
Conclusion:
The O-RADS scoring using non-dynamic MRI is a reproducible method and has good discrimination for borderline/malignant lesions. Potential factors that may lead to discordant ratings are provided here.
More Related Videos
07:32Standardized Histomorphometric Evaluation of Osteoarthritis in a Surgical Mouse Model
Published on: May 6, 2020
08:19Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
Published on: May 17, 2018
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies IV: Magnetic Resonance Imaging