Related Experiment Video
Updated: Jun 11, 2025

Surgical Techniques for Catheter Placement and 5/6 Nephrectomy in Murine Models of Peritoneal Dialysis
Published on: July 19, 2018
Plasma volume response patterns and a physiologic model of ultrafiltration in hemodialysis
Mauro Pietribiasi1, Nicos Mitsides2,3, Jacek Waniewski1
1Department of Modelling and Supporting of Internal Organ Functions, Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Science, Warsaw, Poland.
Background:
Ultrafiltration (UF) is an essential process of restoring fluid homeostasis during hemodialysis (HD). Fluid shifts across the extracellular compartments during UF, predominantly across the capillary interface and between the macro- and microcirculation. A mismatch between UF and transcapillary fluid transport can lead to hemodynamic instability leading to cardiac morbidity. We wished to study intradialytic fluid transport characteristics and their variation during UF to identify factors that govern variability in transcapillary fluid movement in HD.
Methods:
Twenty-two patients undergoing stable HD sessions were studied to measure and monitor absolute blood and plasma volume throughout UF. A computational mathematical model of predicted plasma volume decay during UF was analyzed with respect to the intradialytic real-time data profile. Pre- and post-dialysis fluid status was assessed using multifrequency bioimpedance spectroscopy. Serum electrolytes, osmolality, and total protein concentration were measured pre- and post-dialysis and during the intradialytic phase.
Results:
Two distinct profiles of PV responses were detected. 60% of the patients presented plasma volume decline, characterized by a high percentage of volume decrease during the first hour, and a subsequent slower decrease with early rebound. The model was modified to achieve a proper fit of these volume profiles, assuming time-dependent changes in selected parameters governing the refilling flow.
Conclusions:
Although the modified model could more accurately fit the data, the new parameter values often fell outside of a physiologically acceptable range, suggesting that other factors not included in the classic description of transcapillary fluid transport might be the cause of the observed patterns.
Related Concept Videos
Hemodialysis II: Procedure and Complications
Physiology of the Genitourinary System I: Renal Blood Flow and Glomerular Filtration
Hemodialysis III: Nursing Management
Continuous Renal Replacement Therapy
Physiology of the Genitourinary System II: Tubular Reabsorption and Secretion
Filtration and Urine Formation