Related Experiment Video
Updated: Jul 18, 2026

Intravascular Delivery of Biologics to the Rat Kidney
Published on: September 1, 2016
Mouse Renal Artery Catheterization for Local Delivery of Drugs in Capsulated or Free Forms
Olga A Sindeeva1, Olga I Gusliakova1,2, Ekaterina S Prikhozhdenko2
1Vladimir Zelman Center for Neurobiology and Brain Rehabilitation, Skolkovo Institute of Science and Technology, Moscow, Russia.
Abstract:
Arterial delivery to the kidney offers significant potential for targeted accumulation and retention of cells, genetic material, and drugs, both in free and encapsulated forms, because the entire dose passes through the vessels feeding this organ during the first circulation of blood. At the same time, a detailed study on the safety and effectiveness of developed therapies in a large number of experimental animals is required. Small laboratory animals, especially mice, are the most sought-after in experimental and preclinical testing due to their cost-effectiveness. Most of the described manipulations in mice involve puncturing the walls of the abdominal aorta or renal artery for direct administration of solutions and suspensions. Such manipulations are temporary and, in some cases, result in long-term occlusion of the aorta. Ultimately, this can lead to disruption of blood flow as well as functional and morphological changes to the kidneys. In addition, few of these protocols describe targeted delivery to the kidney. The presented protocol involves the injection of test substances or suspensions through the renal artery into one of the kidneys. The catheter is implanted into the femoral artery and then advanced into the abdominal aorta and renal artery within the vessels. In this case, the integrity violation of the renal artery or abdominal aorta is absent. Occlusion of the renal artery is necessary only immediately at the time of injection to minimize the entry of the injected substance into the aorta. This protocol is similar to the clinical procedure for delivering a catheter into the renal artery and is designed for real-world operating conditions. Key features • The protocol involves implantation of a catheter into the vascular system through a puncture of the femoral artery, similar to the clinical procedure. • The catheter is moved inside the vessels without puncture or ligation to the aorta or renal artery. • The protocol involves only a short-term block of the blood supply to the target kidney (the time required for direct administration of the drug). • Suitable for chronic experiments on mice, since the catheter is removed from the vascular system immediately after drug administration.
Insights
This study presents a novel, minimally invasive catheter technique for targeted renal artery drug delivery in mice. This method enhances safety and effectiveness for preclinical kidney research, avoiding major vessel damage.
Area of Science:
- Biomedical Engineering
- Preclinical Research
- Vascular Interventions
Background:
- Arterial delivery to the kidney allows targeted drug and cell accumulation.
- Current mouse models often use invasive techniques causing vessel damage and kidney issues.
- There's a need for safer, more effective targeted renal delivery methods in preclinical studies.
Purpose of the Study:
- To develop and validate a minimally invasive catheter-based protocol for targeted renal artery administration in mice.
- To improve the safety and reproducibility of preclinical kidney research models.
- To facilitate chronic experiments requiring repeated targeted renal delivery.
Main Methods:
- Catheter implantation via femoral artery puncture, advanced to the renal artery.
- Minimally invasive approach avoiding aorta or renal artery puncture/ligation.
- Short-term, temporary occlusion of the renal artery during injection.
- Catheter removal post-administration for potential chronic use.
Main Results:
- Successfully demonstrated catheter placement and substance delivery into the renal artery without major vessel damage.
- Protocol avoids long-term occlusion, minimizing risk of kidney damage.
- Method is adaptable for repeated administrations in chronic studies.
- Procedure mimics clinical renal artery catheterization techniques.
Conclusions:
- The presented protocol offers a safer, more effective alternative for targeted renal artery delivery in mice.
- This technique advances preclinical kidney research by improving model reliability and reducing animal distress.
- The approach's similarity to clinical procedures supports its translational potential.