Holter Monitor: 24-Hour Monitoring01:23

Holter Monitor: 24-Hour Monitoring

Holter monitoring is a continuous electrocardiography (ECG) recording that tracks the heart's electrical activity over an extended period, generally 24 to 48 hours. This noninvasive diagnostic tool detects irregular heart rhythms that may not be captured during a standard ECG performed in a clinical setting.DeviceThe Holter monitor is a portable, small device connected to several electrodes on the patient's chest. These electrodes detect the heart's electrical signals and transmit them to the...
Methods of Documentation VII: EMR01:30

Methods of Documentation VII: EMR

Electronic Medical Records (EMRs) primarily center around electronically documenting patients' health information within a single healthcare organization or practice. They contain essential clinical data related to a patient's medical history, diagnoses, medications, treatment plans, lab results, and other pertinent information relevant to the specific encounter or episode of care. EMRs are designed to streamline documentation and workflow processes within individual healthcare settings,...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Durvalumab with Gemcitabine and Oxaliplatin in Advanced Biliary Tract Cancer.

Cancers·2026
Same author

Financial Toxicity of Shorter Versus Longer Partial Breast Irradiation: A Randomized Clinical Trial.

International journal of radiation oncology, biology, physics·2026
Same author

All-Oral Combination of Revumenib, Decitabine, and Venetoclax for Relapsed or Refractory AML (SAVE).

Journal of clinical oncology : official journal of the American Society of Clinical Oncology·2026
Same author

Impact of Dedicated Care Coordination on Access to Multidimensional Support Services in Young-Onset Colorectal Cancer: A Pragmatic Trial.

JCO oncology practice·2026
Same author

Addition of Metastasis-Directed Therapy to Standard of Care for Oligometastatic Disease: Primary Aggregated Analysis of All Baskets from the Phase II Randomized EXTEND Trial.

Journal of clinical oncology : official journal of the American Society of Clinical Oncology·2026
Same author

Definitive, stereotactic ablative radiotherapy and endocrine therapy without surgery for select low-risk breast cancers: A prospective, phase II trial.

Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology·2026

Related Experiment Video

Updated: Jun 16, 2026

Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
05:51

Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health

Published on: February 21, 2025

371

Automated, Real-Time Integration of Biometric Data From Wearable Devices With Electronic Medical Records: A

Julius K Weng1, Ritupreet Virk2, Kels Kaiser2

  • 1Department of Radiation Oncology, City of Hope Orange County Lennar Foundation Cancer Center, Irvine, CA.

JCO Clinical Cancer Informatics
|September 30, 2024
PubMed
Summary

This study shows that integrating Apple Watch biometric data into electronic medical records (EMRs) for radiotherapy patients is feasible. Physician review and patient satisfaction were high, supporting future wearable data collection.

More Related Videos

Setup of Consumer Wearable Devices for Exposure and Health Monitoring in Population Studies
15:00

Setup of Consumer Wearable Devices for Exposure and Health Monitoring in Population Studies

Published on: February 3, 2023

2.4K
An Application for Pairing with Wearable Devices to Monitor Personal Health Status
06:58

An Application for Pairing with Wearable Devices to Monitor Personal Health Status

Published on: February 3, 2022

2.7K

Related Experiment Videos

Last Updated: Jun 16, 2026

Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
05:51

Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health

Published on: February 21, 2025

371
Setup of Consumer Wearable Devices for Exposure and Health Monitoring in Population Studies
15:00

Setup of Consumer Wearable Devices for Exposure and Health Monitoring in Population Studies

Published on: February 3, 2023

2.4K
An Application for Pairing with Wearable Devices to Monitor Personal Health Status
06:58

An Application for Pairing with Wearable Devices to Monitor Personal Health Status

Published on: February 3, 2022

2.7K

Area of Science:

  • Oncology
  • Digital Health
  • Medical Informatics

Background:

  • Lack of device integration with electronic medical records (EMRs) hinders clinical use of biometric data.
  • Developed infrastructure to transmit Apple Watch data into EMR for physician review.
  • Tested feasibility in patients undergoing radiotherapy.

Purpose of the Study:

  • Evaluate the feasibility of integrating biometric data from an Apple Watch into EMR for radiotherapy patients.
  • Assess physician review rates and patient satisfaction with the system.

Main Methods:

  • Included breast/prostate cancer patients receiving radiotherapy and owning an Apple Watch.
  • Transferred daily heart rate, HR variability, steps, and exercise minutes to EMR via a custom app.
  • Radiation oncologists reviewed data weekly; feasibility defined as ≥90% physician review.

Main Results:

  • Met feasibility threshold: 95% of patients had data reviewed by physicians.
  • Exercise minutes decreased over time (P=.01) in longer radiation courses (≥4 weeks).
  • Daily mean HR variability increased over time (P=.02); median System Usability Scale (SUS) was 82.5.

Conclusions:

  • Demonstrated feasibility of real-time biometric data integration from Apple Watch to EMR.
  • High physician review rates and patient satisfaction support further development.