Related Experiment Video
Updated: Jun 11, 2025

Real-Time Void Spot Assay
Published on: February 10, 2023
Development and Validation of a Prediction Model for Estimating 24-Hour Urinary Sodium Excretion Using Spot Urine
Miriam Menacho-Roman1, Martin Fabregate-Fuente2, Laura Caja-Guayerbas1
1Clinical Biochemistry Department, Hospital Universitario Ramón y Cajal, IRYCIS, Madrid, Spain.
Introduction:
The measurement of urinary sodium excretion provides valuable information about an individual's sodium balance and can help in the management of various medical conditions. However, the collection of 24-hour urine samples is subject to errors. Spot urine sodium (uNa) measurements are a reliable alternative to 24-hour urine collections for estimating urinary sodium excretion.
Objective:
To assess whether 24-h urinary sodium excretion (24 h uNa) can be estimated from spot samples in adult patients who attend hospital clinics.
Design And Methods:
A cross-sectional study with a development (284 patients) and a validation cohort (229 patients) was conducted at our hospital. A multivariate linear regression model was built which was compared with former models. Concordance analyses and comparison of the ability to correctly classify each patient against a prespecified uNa cutoff value of 130 mmol/24 h were performed, assessed by the C-statistic.
Results:
The model was well calibrated (slope [95% confidence interval] in internal validation: 0.965 [0.947-0.987], showing good discrimination, and performed robustly in an external validation cohort (slope: 0.811 [0.675-0.946]). The mean bias between the measured and the estimated 24 h uNa by NaRYC was 24.85 mmol/24 h [17.06-32.63]. The NaRYC had the highest values of Pearson coefficient (0.613 P < .0001), accuracy (the percentage of estimated 24 h uNa results within 30% deviation of measured 24 h uNa): 56.8%, and area under the receiver operating characteristic curve: 0.822 [0.766-0.869] as compared to other seven equations.
Conclusion:
Although the mean bias of the results is quite acceptable, the variability observed in the 95% confidence interval makes not recommend the general use of a spot as a substitute of the 24-hour urine in order to estimate the total urine excretion of Na in a single subject basis.
Related Concept Videos
One-Compartment Open Model: Urinary Excretion Data and Determination of k
Nephrotic Syndrome II : Assessment and Medical Management
Urine Studies I: Urinalysis
Serum Studies: Renal Function Tests
Urine Studies II: Urine Culture and Sensitivity Test
Formation of Concentrated Urine