Radiation Exposure During Invasive Cardiovascular Procedures: Portable Shielding System Versus Standard Lead Aprons
Husam A Noor1, Noof Althawadi1, Zaina Noor1
1Cardiology Department, Mohammed Bin Khalifa Specialist Cardiac Centre (MKCC), Awali, BHR.
Abstract:
Introduction Significant progress in the field of interventional cardiology has led to a rise in percutaneous procedures and an increase in the risk of radiation exposure at the workplace. Staff health has been put at risk due to the limitations of conventional radiation protective techniques. Innovative methods, such as RAMPART, have promising prospects for enhancing radiation safety. The purpose of this study was to evaluate RAMPART's effectiveness and practicality in comparison to conventional protective techniques with a lead apron and shield (LAS) during cardiac interventional procedures. Method One hundred elective cardiac procedures were enrolled in this prospective single-center research study. Two groups were formed from the participants: standard protection (group A) and RAMPAT system (group B). Real-time dosimeters were used to track the radiation dosage, dosage reduction factor, dosage reduction percentage, and likelihood of exceeding the limit, which were included in the data. Proceduralists were urged to use different strategies to reduce exposure. The study was approved by an ethical committee and ran from June 2023 to August 2023. Results When comparing the RAMPART group to the conventional protection group, neck-level radiation exposure was considerably lower for all workers. There were no notable variations in the exposure of the waist. The RAMPART group was shown to be superior in minimizing radiation exposure, as evidenced by dose reduction metrics. The groups had comparable procedural characteristics. Conclusion Compared to conventional LAS, the RAMPART system dramatically reduces radiation exposure to the entire body.
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Nuclear Power
Nuclear Fuels
Nuclear fuel consists of a fissile isotope, such as uranium-235, which must be present in sufficient quantity to provide a...
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Biological Effects of Radiation


