Related Experiment Video
Updated: Jun 19, 2026

Catheter Ablation in Combination With Left Atrial Appendage Closure for Atrial Fibrillation
Published on: February 26, 2013
Multielectrode catheter-based pulsed field ablation of persistent and long-standing persistent atrial fibrillation
Domenico G Della Rocca1,2, Antonio Sorgente1, Luigi Pannone1
1Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Av. du Laerbeek 101, 1090 Jette, Brussels, Belgium.
Aims:
Rhythm control of non-paroxysmal atrial fibrillation (AF) is significantly more challenging, as a result of arrhythmia perpetuation promoting atrial substrate changes and AF maintenance. We describe a tailored ablation strategy targeting multiple left atrial (LA) sites via a pentaspline pulsed field ablation (PFA) catheter in persistent AF sustained beyond 6 months (PerAF > 6 m) and long-standing persistent AF (LSPAF).
Methods And Results:
The ablation protocol included the following stages: pulmonary vein antral and posterior wall isolation plus anterior roof line ablation (Stage 1); electrogram-guided substrate ablation (Stage 2); atrial tachyarrhythmia regionalization and ablation (Stage 3). Seventy-two [age:68 ± 10years, 61.1%males; AF history: 25 (18-45) months] patients with PerAF > 6 m (52.8%) and LSPAF (47.2%) underwent their first PFA via the FarapulseTM system. LA substrate ablation (Stage 1 and 2) led to AF termination in 95.8% of patients. AF organized into a left-sided atrial flutter (AFlu) in 46 (74.2%) patients. The PFA catheter was used to identify LA sites showing diastolic, low-voltage electrograms and entrainment from its splines was performed to confirm the pacing site was inside the AFlu circuit. Left AFlu termination was achieved in all cases via PFA delivery. Total procedural and LA dwell times were 112 ± 25 min and 59 ± 22 min, respectively. Major complications occurred in 2 (2.8%) patients. Single-procedure success rate was 74.6% after 14.9 ± 2.7 months of follow-up; AF-free survival was 89.2%.
Conclusion:
In our cohort, PFA-based AF substrate ablation led to AF termination in 95.8% of cases. Very favourable clinical outcomes were observed during >1 year of follow-up.