Related Experiment Video
Updated: Jun 11, 2025

Measuring the Complete-arch Distortion of an Optical Dental Impression
Published on: May 30, 2019
Comparison of the reverse scan technique with an intraoral scanner and the traditional impression technique
Pavel Hyspler1, Petra Urbanová2, Tatjana Dostalova3
1Head, Dental Department, The Military University Hospital Prague, Prague, Czech Republic; and PhD student, Charles University, 1st Medical Faculty, Prague, Czech Republic.
Statement Of Problem:
Intraoral scanners have many advantages but have limited applicability for extensive tooth-supported or implant-supported prostheses because of merging errors.
Purpose:
The purpose of this study was to compare the reverse scan technique (RST) with an intraoral scanner using the traditional impression technique both in vitro and in vivo.
Material And Methods:
A participant was scanned 10 times with an intraoral scanner. Then, the RST was performed 3 times in the oral cavity. One of the intraoral scans was chosen to make a 3-dimensionally (3D) printed cast. The printed cast was scanned 10 times with a laboratory scanner (Control cast) and 10 times with an intraoral scanner (IOS cast). The RST was performed 10 times (RST cast), and 10 dental impressions were made using the traditional splinted technique on the same cast (Impression cast). A laboratory scanner was used to obtain standard tessellation language (STL) files of the tested methods. A newly developed pyramid replacement method was used to evaluate accuracy. This method uses modified virtual abutments with integrated pyramids that determine the exact measurement points. The obtained data were processed using Procrustes analysis and statistically analyzed (α=.05).
Results:
The Procrustes distances were Control cast 0 to 0.4 µm (median 0.3 µm), RST cast 5.6 to 6.9 µm (median 6.2 µm), Impression cast 5.4 to 7.1 µm (median 6.5 µm), and IOS cast group 4.5 to 41.2 µm (median 5.8 µm). In the participant, the Procrustes distance values were RST intraoral 9.5 to 9.6 µm (median 9.5 µm) and IOS intraoral 5.7 to 18.3 µm (median 10.9 µm).
Conclusions:
The reverse scan technique is an acceptable fully digital replacement for traditional impression making. Using an IOS to obtain a 3D cast of an implant-supported interim prosthesis with scannable implant analogs is not recommended. It is more beneficial to use laboratory scanners rather than intraoral scanners for the digitization of precision improvement devices such as bonded interim implant-supported prostheses with a scannable implant analog or solid index.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Overview of Microscopy Techniques
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...

