Related Experiment Video
Updated: Jun 11, 2025

Observational Study Protocol for Repeated Clinical Examination and Critical Care Ultrasonography Within the Simple Intensive Care Studies
Published on: January 16, 2019
Point-of-care creatinine vs. central laboratory creatinine in the critically ill
Kyle C White1,2,3, James McCullough4,5, Kiran Shekar2,3,6
1Intensive Care Unit, Princess Alexandra Hospital, Woolloongabba, Queensland, Australia.
Objective:
Frequent measurement of creatinine by point-of-care testing (POCT) may facilitate the earlier detection of acute kidney injury (AKI) in critically ill patients. However, no robust data exist to confirm its equivalence to central laboratory testing. We aimed to conduct a multicenter study to compare POCT with central laboratory creatinine (CrC) measurement.
Design:
Retrospective observational study, using hospital electronic medical records. Obtained paired point-of-care creatinine (CrP) from arterial blood gas machines and CrC.
Setting:
Four intensive care units in Queensland, Australia.
Participants:
Critically ill patients, where greater than 50% of POCT contained creatinine.
Main Outcome Measures:
Mean difference, bias, and limits of agreement between two methods, and biochemical confounders.
Results:
We studied 79,767 paired measurements in 19,118 patients, with a median Acute Physiology and Chronic Health Evaluation 3 score of 51. The mean CrC was 115.5 μmol/L (standard deviation: 100.2) compared to a CrP mean of 115 μmol/L (standard deviation: 100.7) (Pearson coefficient of 0.99). The mean difference between CrP and CrC was 0.49 μmol/L with 95% limits of agreement of -27 μmol/L and +28 μmol/L. Several biochemical variables were independently associated with the difference between tests (e.g., pH, potassium, lactate, glucose, and bilirubin), but their impact was small.
Conclusion:
In critically ill patients, measurement of creatinine by POCT yields clinically equivalent values to those obtained by central laboratory measurement and can be easily used for more frequent monitoring of kidney function in such patients. These findings open the door to the use of POCT for the earlier detection of acute kidney injury in critically ill patients.
Related Concept Videos
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...
Determination of Renal Drug Clearance: Graphical and Midpoint Methods
The graphical method involves plotting the rate of drug excretion in urine against the plasma drug concentration. By analyzing the graph, the clearance can be calculated and obtained. Drugs rapidly excreted by the kidneys exhibit a...
Serum Studies: Renal Function Tests
Acute Kidney Injury IV: Diagnostic Studies and Prevention
Acute Kidney Injury I: Introduction