Wearable Devices Based on Bioimpedance Test in Heart-Failure: Design Issues
Santiago F Scagliusi1, Luis Giménez-Miranda2, Pablo Pérez-García1
1Institute of Microelectronics of Seville - Spanish National Center of Microelectronics (IMSE-CNM) University of Seville, 41092 Seville, Spain.
Wearable bioimpedance (BI) devices offer a non-invasive, cost-effective solution for real-time heart failure (HF) monitoring outside clinical settings. This review details BI device specifications for optimal HF patient management and remote health tracking.
Area of Science:
- Biomedical Engineering
- Medical Technology
- Cardiology
Background:
- Heart failure (HF) necessitates continuous patient monitoring for effective management.
- Current monitoring methods often require hospitalization or frequent clinical visits.
- Physicians require accessible tools to track HF patient biomarker evolution remotely.
Purpose of the Study:
- To systematically review wearable bioimpedance (BI) devices for real-time heart failure (HF) monitoring.
- To outline essential design and implementation specifications for practical medical use.
- To identify key challenges and approaches in developing BI-based HF monitoring systems.
Main Methods:
- Systematic literature review of wearable BI devices for HF.
- Analysis of BI applications in heart failure management.
- Evaluation of sensing techniques, impedance specifications, electrode selection, and device design factors (portability, communication, power).
Main Results:
- Bioimpedance (BI) is a viable non-invasive technology for sensing physiological variables in portable systems.
- Key specifications for wearable BI devices in HF monitoring include sensing technique, impedance parameters, electrode choice, portability, communication, and power consumption.
- Various design and implementation strategies by engineering and clinical teams were identified.
Conclusions:
- Wearable BI devices present a promising, non-expensive, and non-invasive approach for remote heart failure monitoring.
- Optimizing device design and implementation is crucial for effective clinical application and patient management.
- Further research is needed to address current challenges in wearable BI technology for HF.
More Related Videos
10:21Evaluation of Hydration Status by Bioelectrical Impedance Vector Analysis in Patients with Ischemic Heart Disease Undergoing Exercise Stress Test
Published on: September 22, 2023
10:03Conformable Wearable Electrodes: From Fabrication to Electrophysiological Assessment
Published on: July 22, 2022
Related Concept Videos
Heart Failure V: Nursing Interventions
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...