Related Experiment Video
Updated: Jun 11, 2025

Author Spotlight: Exploring Breathing Techniques and Digital Solutions for Enhancing Running Performance
Published on: September 27, 2024
Wearable Applicability of Respiratory Airflow Transducers: Current Approaches and Future Directions
Lu Jin1, Jiahao Li1,2,3, Yifan Yang1
1Yiwu Research Institute of Fudan University, Yiwu, Zhejiang 322000, People's Republic of China.
Abstract:
Advanced technologies employed in modern respiratory airflow transducers have exhibited powerful capabilities in accurately measuring respiratory flow under controlled and sedentary conditions, particularly in clinical settings. However, the wearable applicability of these transducers as face-mounted electronics for use in occupational and sporting activities remains unexplored. The present review addresses the critical wearability issue associated with current respiratory airflow transducers, including pneumotachographs, orifice flowmeters, turbine flowmeters, hot wire anemometers, ultrasound flowmeters, and piezoelectric airflow transducers. Furthermore, a comprehensive analysis and comparison of all factors that impact the wearable applicability of respiratory airflow transducers are conducted, considering dynamic accuracy, long-term usability, power consumption, calibration frequency, and cleaning requirements. The findings indicate that the piezoelectric airflow transducer stands out as a more viable option for wearables compared to other devices. We expect that this review will serve as a valuable engineering reference, guiding future research efforts in designing and developing wearable respiratory airflow transducers for ambulatory respiratory flow monitoring.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...

