Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Coronary Artery Disease V: Surgical Management01:27

Coronary Artery Disease V: Surgical Management

3
Interprofessional care for coronary artery disease includes pharmacological therapy and revascularization procedures.Pharmacological therapy for Coronary Artery Disease (CAD) aims to manage symptoms, prevent complications, and improve patient outcomes through various classes of medications:Antiplatelet Agents:Aspirin and Clopidogrel: These medications inhibit platelet aggregation, preventing blood clots, which is crucial for avoiding heart attacks and strokes. Doctors often prescribe these...
3
Coronary Artery Disease IV: Medical Management01:26

Coronary Artery Disease IV: Medical Management

11
Effective preventive measures for coronary artery disease (CAD) focus on controlling modifiable risk factors, including cholesterol abnormalities and lifestyle changes.Cholesterol ManagementFirst, the Mediterranean diet and the American Heart Association advocate for maintaining low-density lipoprotein (LDL) cholesterol levels below 100 mg/dL, with a more stringent recommendation of below 70 mg/dL for individuals at high risk. LDL cholesterol, often termed "bad cholesterol," can lead to the...
11
Heart Valves01:16

Heart Valves

4.4K
The human heart is a complex organ with an intricate system of valves that regulate blood flow. There are two main types of valves: atrioventricular (AV) valves and semilunar valves.
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
4.4K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Prosthesis-patient mismatch with intra-annular self-expanding valves: an analysis of the PORTICO IDE trial.

EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology·2026
Same author

Residual Mitral Regurgitation-Mean Gradient Trade-Off: A New Paradigm in Mitral Transcatheter Edge-to-Edge Repair.

JACC. Cardiovascular imaging·2026
Same author

Redo Transcatheter Aortic Valve Replacement for Degenerated Valve With High-Risk Coronary Anatomy.

JACC. Case reports·2026
Same author

Balloon-Assisted Leaflet Laceration Using Modified UNICORN Technique in Native Valve TAVR.

JACC. Case reports·2026
Same author

Redo-TAVR (TAV-in-TAV) Best Practices Part 1: Short-in-Short and Short-in-Tall - A Heart and Valve Collaboratory Document.

JACC. Cardiovascular interventions·2026
Same author

Redo-TAVR (TAV-in-TAV) Best Practices Part 2: Tall-in-Short and Tall-in-Tall - A Heart and Valve Collaboratory Document.

JACC. Cardiovascular interventions·2026

Related Experiment Video

Updated: Jun 11, 2025

Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
06:59

Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation

Published on: June 3, 2018

10.6K

Transcatheter Aortic Valve Implantation Using the Evolut FX+ Platform With Optimal Diamond-Coronary Alignment.

Joe Aoun1, Chloe Kharsa1, Michael Reardon2

  • 1Department of Cardiology, Houston Methodist DeBakey Heart and Vascular Center, Houston, Texas, USA.

JACC. Case Reports
|October 3, 2024
PubMed
Summary

This study details the first use of the Medtronic Evolut FX+ transcatheter aortic valve implantation system. The procedure showed successful coronary angiography and optimal valve alignment post-operation.

Area of Science:

  • Cardiovascular Medicine
  • Interventional Cardiology
  • Medical Device Technology

Background:

Keywords:
Evolut FX+aortic stenosiscommissural alignmentcoronary accesstranscatheter aortic valve implantation

More Related Videos

The WATCHMAN Left Atrial Appendage Closure Device for Atrial Fibrillation
23:33

The WATCHMAN Left Atrial Appendage Closure Device for Atrial Fibrillation

Published on: February 28, 2012

83.5K
Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
13:48

Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound

Published on: April 21, 2023

1.4K

Related Experiment Videos

Last Updated: Jun 11, 2025

Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
06:59

Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation

Published on: June 3, 2018

10.6K
The WATCHMAN Left Atrial Appendage Closure Device for Atrial Fibrillation
23:33

The WATCHMAN Left Atrial Appendage Closure Device for Atrial Fibrillation

Published on: February 28, 2012

83.5K
Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
13:48

Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound

Published on: April 21, 2023

1.4K
  • Transcatheter aortic valve implantation (TAVI) is a minimally invasive alternative to surgical aortic valve replacement.
  • Advancements in TAVI platforms aim to improve procedural efficiency and patient outcomes.
  • The Medtronic Evolut FX+ represents a new generation of TAVI technology.